Webinars and Sponsored Roundtables — Register Now

Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.

Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Center, and Colin Murphy,  CEO of mTuitive.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, June 9, 2026, 1:00–2:00 PM ET
In this webinar, we will examine how immune recognition after allogeneic HCT can influence leukemia relapse and disease progression. The session will highlight the clinical relevance of HLA loss of heterozygosity (LOH), approaches used for its detection, and how LOH findings may support transplant strategies, including considerations for donor selection in subsequent transplantation.

Webinar presenter Alberto Cardoso Martins Lima, PhD, Clinical consulting scientist in histocompatibility,
specializing in allogeneic hematopoietic cell transplantation (HCT) at IGEN/AFIP São Paulo and CHC/UFPR in Curitiba, Brazil

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, June 24, 2026, 12:00–1:00 PM ET
Hear an expert discuss the expanded clinical utility of HER2 IHC scoring in metastatic breast cancer and its impact on your practice

Webinar presenter Michelle Shiller, DO, AP, CP, MGP, FACP, Baylor University Medical Center.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

LABiTec LAbor BioMedical Technologies GmbH

CoaLAB 1000

Company

LABiTec LAbor BioMedical Technologies GmbH

Instrument name/First year sold

CoaLAB 1000/—

Contact

M. Schramm  

Email

info@labitec.de

City, State

Ahrensburg, Germany

Phone

011-49-4102-47950  

Website

https://www.labitec.com

List price/Model type

—/benchtop

No. of units in clinical use in U.S./Outside U.S.

—/— (worldwide [except U.S., Canada])

Composition of installs: Hospital lab/Reference lab/Other

Targeted daily, monthly, annual test volume

daily: 100–400; monthly: 2, 000–8, 000; annual: 24, 000–95, 000

Operational type

batch, random access

Country where analyzer designed/Manufactured

Germany/Germany

Company manufactures instrument

yes (also sold via OEM distribution, local distributors)

FDA-approved clotting-based tests

FDA-approved chromogenic tests

FDA-approved immunologic tests

Other FDA-approved tests

User-defined tests in clinical use

Tests in development or awaiting FDA 510(k) clearance

Methodologies supported

clot detection, mechanical and optical; photometric with mechanical stirring, turbodensitometric; chromogenic; immunologic (photometric)

Number of different measured assays onboard simultaneously

15

Number of different assays programmed and calib. at one time

50

No. of user-definable (open) channels/No. active simultaneously

50/15

Factor assays require manual manipulation or dilutions

Test throughput per hour/Assay run time

120 PT tests/—

Design of sample-handling system

cuvette ring, sample cups

Operates on whole blood or spun plasma

spun plasma

Reagent type

self-contained single-use vials; open reagent system (liquid, lyophilized [reconstituted manually])

Reagent barcode-reading capability

yes, for some tests

No. of reagent containers held onboard/Reagents ready to use

15/yes

Reagent lot tracking/Reagent inventory/Reagents refrigerated onboard

yes/yes/no

Reagents, consumables loaded without interrupting testing

yes (reagents)

Instrument uses proprietary or third-party reagents

user’s option (same capabilities when third-party reagents used)

Maximum time same lot number of reagents can be used

Walkaway capability/Walkaway duration

yes/22 samples plus 3 stat (reagent dependent)

Min.–max. specimen volume that can be aspirated at one time

2–275 µL

Min. sample volume required for PT/PTT/Factor VIII activity

Primary tube sampling supported/Pierces caps on primary tubes

yes/no

Accommodates most standard tube sizes/Nonstandard sizes

yes/no

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128)/no

More products
in this guide

PAP-8E Platelet Aggregometer
Optical Aggregation Systems Models 490 4+ | 490 4+4
Whole Blood Optical Lumi-Aggregation System 700-2 | 700-4
Quantra Hemostasis Analyzer
Sysmex CA-600 Series Systems: CA-620 | CA-660
Sysmex CS-2500 System
Sysmex CS-5100 System
ACL TOP 550 CTS
ACL TOP 750 Series
ACL TOP 770/770s
ACL TOP 770 LAS