Webinars and Sponsored Roundtables — Register Now

Tuesday, April 28, 2026, 12:00 PM–1:00 PM ET
Discover how next-day comprehensive genomic profiling (CGP) is possible with the Oncomine Comprehensive Assay Plus on the Genexus System—delivering both speed and accuracy.

Webinar presenters Jane Bayani, MHSc, PhD, Assistant Professor and Co-Director, Diagnostic Development, Ontario Institute for Cancer Research, Canada, and Nicola Normanno, MD, Scientific Director, IRCCS Romagnolo Institute for the Study of Tumors, Italy, and Morten Grauslund, PhD, Molecular Biologist, Department of Pathology, Rigshospitalet/Copenhagen University Hospital, Copenhagen, Denmark.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Thermo Fisher Scientific. For Research Use Only. Not for use in diagnostic applications. 

Thursday, April 30, 2026, 11:00 AM–12:00 PM ET
Hear an expert discuss how Memorial Sloan Kettering Cancer Center (MSKCC) is utilizing
the oncoReveal® Nexus 21-gene panel to redefine turnaround time and actionable insights
in cancer care. Dr. Ewalt shares a perceptive look at the clinical need for rapid, front-line NGS sequencing, and how a unique, purpose built targeted NGS panel (Pillar Biosciences’ oncoReveal Nexus 21 gene Panel) was developed, validated and implemented clinically by Memorial Sloan Kettering Cancer Center (MSK-REACT) to complement their current comprehensive genomic profiling (CGP) approach.

Webinar presenter Mark Ewalt, MD, Associate Medical Director for Laboratory Operations for Diagnostic Molecular Pathology in the Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, MSKCC.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Pillar Biosciences.

Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.

Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Cente, and Colin Murphy,  CEO of mTuitive.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Gold Standard Diagnostics

AIX1000 Agglutination Instrument

Company

Gold Standard Diagnostics

Name of instrument

AIX1000 Agglutination Instrument

Contact

Christina Brusca 

Email

christina.brusca@us.goldstandarddiagnostics.com

City, State

Davis, CA

Phone

530-759-8000  

Website

https://www.gsdx.us

Type of instrument

immunoassay

Operational type/Model type

batch/benchtop

List price/First year sold in U.S.

—/2016

Targeted hospital bed size/Targeted test volume

Company manufactures instrument

yes (also sold by Cardinal Health, Thermo Fisher Scientific, VWR)

Other models in this family of analyzers

No. of units in clinical use in U.S./Outside U.S. (countries)

Dimensions (H × W × D)/Instrument footprint

17.7 x 25.3 x 22.5 in./4.1 sq. ft.

Weight empty/Weight fully loaded

62 lbs./~110 lbs.

No. of different measured assays onboard simultaneously

2 (2 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

Test throughput per hour/Assay run time

128 (128 tests in throughput)/75 min.

No. of direct ion-selective electrode channels

Detection methods

• Ion-selective electrode

• Basic metabolic panel

• Complete metabolic panel

Typical time delay from ordering stat test until aspiration of sample

Fully automated microplate immunoassay system

no

Methodologies supported

agglutination

Separation methodologies

none necessary

Stat time until completion of a ß-hCG test

Stat time until completion of a cTn test

• Typical time delay from test order to aspiration of sample

Approximate No. of tests per reagent set/Reagent type

480/self-contained multiuse

Reagents refrigerated onboard/Reagents ready to use

no/—

Reagent lot tracking/Reagent inventory

no/no

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/20–90 min. 

Design of sample-handling system

universal slide-in racks

Uses washable cuvettes/Uses disposable cuvettes

no/no

Min.–max. sample volume that can be aspirated at one time 

1–150 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

105 µL/300 µL/150 µL

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes (12–16 x up to 100 mm)

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

no/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

hemolysis, icterus, lipemia, clots not available 

Dilutes patient samples onboard/Susceptibility to carryover

yes/—

Sample volume can be diluted to rerun out-of-linear-range high results

no

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Analyzer requires dedicated water supply

no (0.045 L/hr. consumption during operation)

Autocalibration/Multipoint calibration supported

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

Automatic programmable start/Automatic programmable shutdown

no (< 5 min. start-up time)/no

Supports multiple QC lot numbers per analyte

no

Waste management

manually by user

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128, 1D, 2D)/yes

Lab can control analyzer from remote computer

yes

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

no

Data-management capability/LIS or EHR systems interfaced

onboard/—

LIS interface provided/Bidirectional interface capability

yes/yes

Modem servicing provided/Service engineer on-site response time

Mean time between failures

— (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: < 5 min.; weekly: < 20 min.; monthly: < 5 min.

Maintenance records kept onboard for user/vendor

yes/yes 

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes (minimum 1 training slot)/2 days (at customer site or online)

Advanced operator training/Extra charge for follow-up or advanced training

yes/—

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

universal slide-in racks accommodate a variety of tube sizes for easier and faster sample loading; ability to add SMS and email alerts for notification of errors or test completion; automated processing, analysis, interpretation, and result and image archiving; 90 min. walkaway time for 192 specimens

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Agility Automated ELISA System
Envoy 500/Envoy 500+ Chemistry Analyzer
Yumizen C1200
Yumizen C560
VITROS 4600 Chemistry System
VITROS XT 7600 Integrated System
cobas 6000 analyzer series
cobas 8000 modular analyzer series
cobas pro integrated solutions
dIFine P30 Processor
IMMULITE 2000 XPi Immunoassay System
Phadia 250 Laboratory System