Webinars and Sponsored Roundtables — Register Now

Tuesday, April 28, 2026, 12:00 PM–1:00 PM ET
Discover how next-day comprehensive genomic profiling (CGP) is possible with the Oncomine Comprehensive Assay Plus on the Genexus System—delivering both speed and accuracy.

Webinar presenters Jane Bayani, MHSc, PhD, Assistant Professor and Co-Director, Diagnostic Development, Ontario Institute for Cancer Research, Canada, and Nicola Normanno, MD, Scientific Director, IRCCS Romagnolo Institute for the Study of Tumors, Italy, and Morten Grauslund, PhD, Molecular Biologist, Department of Pathology, Rigshospitalet/Copenhagen University Hospital, Copenhagen, Denmark.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Thermo Fisher Scientific. For Research Use Only. Not for use in diagnostic applications. 

Thursday, April 30, 2026, 11:00 AM–12:00 PM ET
Hear an expert discuss how Memorial Sloan Kettering Cancer Center (MSKCC) is utilizing
the oncoReveal® Nexus 21-gene panel to redefine turnaround time and actionable insights
in cancer care. Dr. Ewalt shares a perceptive look at the clinical need for rapid, front-line NGS sequencing, and how a unique, purpose built targeted NGS panel (Pillar Biosciences’ oncoReveal Nexus 21 gene Panel) was developed, validated and implemented clinically by Memorial Sloan Kettering Cancer Center (MSK-REACT) to complement their current comprehensive genomic profiling (CGP) approach.

Webinar presenter Mark Ewalt, MD, Associate Medical Director for Laboratory Operations for Diagnostic Molecular Pathology in the Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, MSKCC.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Pillar Biosciences.

Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.

Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Cente, and Colin Murphy,  CEO of mTuitive.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Diagnostica Stago

STA-R Max 3

Company

Diagnostica Stago

Instrument name

STA-R Max 3

Contact

Jennifer Blockhaus  

City State

Parsippany, NJ 

Phone

800-222-2624

Website

https://www.stago-us.com

First year sold

2023

List price/Model type

$250, 770/floor standing

Dimensions (H × W × D)/Weight/Instrument footprint

49.2 × 50.3 × 32.2 in./564 lbs./26.8 sq. ft.

No. of units in clinical use in U.S./Outside U.S.

~650/~3, 200 (France, Spain, UK, Germany, Denmark, others)

Composition of installs: Hospital lab/Reference lab/Other

~90%/7%/3% (veterinary labs, pharmaceutical companies, academic research/educational labs)

Targeted daily, monthly, annual test volume

daily: >100 (moderate- to high-volume laboratories); monthly: >2, 500; annual: >25, 000

Operational type

continuous random access

Country where analyzer designed/Manufactured

France/France

Company manufactures instrument

yes

FDA-approved clotting-based tests

PT, APTT, TT, fibrinogen, reptilase, factors, proteins C and S, lupus anticoagulant, DRVVT (screen and confirm)

FDA-approved chromogenic tests

anti-FXa (UFH and LMWH), antithrombin, protein C, plasminogen, FVIII chromogenic

FDA-approved immunologic tests

D-dimer, antithrombin antigen, free protein S, total protein S, vWF antigen (all microlatex)

Other FDA-approved tests

STA NeoPTimal protime reagent with ISI ~1.0

User-defined tests in clinical use

APCR, other clotting, chromogenic, and immunological tests with user-defined applications

Tests in development or awaiting FDA 510(k) clearance

Methodologies supported

mechanical clot detection, chromogenic, immunologic (microlatex)

Number of different measured assays onboard simultaneously

200

Number of different assays programmed and calib. at one time

200

No. of user-definable (open) channels/No. active simultaneously

200/200

Factor assays require manual manipulation or dilutions

Test throughput per hour/Assay run time

280 (2 tests in throughput)/4.6–7.3 min. (avg. 4.7 min.)

Design of sample-handling system

rack with continuous specimen access

Operates on whole blood or spun plasma

spun plasma

Reagent type

self-contained single-use and multiuse vials; open reagent system (liquid, lyophilized [reconstituted manually])

Reagent barcode-reading capability

yes, for all tests

No. of reagent containers held onboard/Reagents ready to use

75/variable (reagent specific)

Reagent lot tracking/Reagent inventory/Reagents refrigerated onboard

yes/yes/yes (15°–19°C)

Reagents, consumables loaded without interrupting testing

yes (consumables)

Instrument uses proprietary or third-party reagents

user’s option (same capabilities when third-party reagents used)

Maximum time same lot number of reagents can be used

18 months

Walkaway capability/Walkaway duration

yes/215 specimens or 32 tests

Min.–max. specimen volume that can be aspirated at one time

5–100 µL

Min. sample volume required for PT/PTT/Factor VIII activity

50 µL/50 µL/50 µL

Types of disposables used

cuvettes, stir bars, cleaner solution

Primary tube sampling supported/Pierces caps on primary tubes

yes/yes

Accommodates most standard tube sizes/Nonstandard sizes

yes/no

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar)/—

Auto tracks product volume/Measures number of tests remaining

yes/no

Short sample detection

yes

Clot detection as preanalytical variable in plasma sample

no

Auto detects adequate reagents for aspiration or analysis

yes (aspiration and analysis)

Detection or quantitation for hemolysis, turbidity, icterus, lipemia 

yes

Dilutes patient samples onboard

yes

Automatic rerun capability/Auto reflex testing capability

yes/yes

Lag time during which hypercoagulable sample not detected

no

User can adjust reagent volumes/Sample volumes

yes/yes

User can adjust No. of reagents/Sources of reagents

yes/yes

User can adjust incubation times/Reading times

yes/yes

Autocalibration/Calibrants stored onboard

yes/yes

Multipoint calibration supported/Recommended frequency

yes/6 months

• PT alone

<6 minutes/~320 specimens

• PT, PTT

<6 minutes/~280 specimens

• Fibrinogen

<6 minutes/~180 specimens

• Factor VIII activity assay

<6 minutes/~180 specimens

• D-dimer

7 minutes/~150 specimens

Time delay from ordering stat to aspiration of sample

<15 seconds

How labs get LOINC codes for results

email query, LOINC codes available in STA Coag Expert

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Information that can be barcode-scanned on instrument

specimen identifier, reagent lot No., quality control ranges, calibrator values

Compatible with laboratory automation systems

yes (Stago, Abbott, Beckman Coulter, Oracle Health, Inpeco, QuidelOrtho, Roche, Siemens)

Data-management capability/LIS or EHR systems interfaced

onboard/Oracle Health, Meditech, Clinisys, SCC, McKesson, Epic

Interface supplied by instrument vendor

contract dependent

Results transferred to LIS as soon as test time complete

yes

Bidirectional interface capability

yes (broadcast download and host query)

Remote servicing provided/UPS backup power supply

yes/yes

Instrument connections to transfer information

data-management system, which in turn connects to LIS; directly to LIS; directly to lab automation system

Interface standards supported

ASTM 1394-91, ASTM 1381

Information transferred to data-management software

device unique identifier, patient ID, specimen ID, result, QC identifier

Avg. time for basic user training

3.5 days (at vendor office)

Approximate scheduled maintenance time

daily: 10 minutes; weekly: 10 minutes; monthly: none

Maintenance records kept onboard

yes

Warranty with purchase/Annual service contract cost (24/7)

yes/— (cost dependent on contract)

Distinguishing features (supplied by company)

viscosity-based, mechanical clot detection; precalibrated D-dimer and fibrinogen reagents, full complement of lupus anticoagulant testing; STA Coag Expert and Coag.One data managers deliver full autoverification, repeat/reflex testing, auto upload of QC to peer group and of CPR test counts

More products
in this guide

PAP-8E Platelet Aggregometer
Optical Aggregation Systems Models 490 4+ | 490 4+4
Whole Blood Optical Lumi-Aggregation System 700-2 | 700-4
Quantra Hemostasis Analyzer
Sysmex CA-600 Series Systems: CA-620 | CA-660
Sysmex CN-3000
Sysmex CN-6000
Sysmex CS-2500 System
Sysmex CS-5100 System
ACL TOP 550 CTS
ACL TOP 750 Series
ACL TOP 770/770s
ACL TOP 770 LAS
ACL TOP 970 CL