Webinars and Sponsored Roundtables — Register Now
Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.
Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Cente, and Colin Murphy, CEO of mTuitive.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, June 9, 2026, 1:00–2:00 PM ET
In this webinar, we will examine how immune recognition after allogeneic HCT can influence leukemia relapse and disease progression. The session will highlight the clinical relevance of HLA loss of heterozygosity (LOH), approaches used for its detection, and how LOH findings may support transplant strategies, including considerations for donor selection in subsequent transplantation.
Webinar presenter Alberto Cardoso Martins Lima, PhD, Clinical consulting scientist in histocompatibility,
specializing in allogeneic hematopoietic cell transplantation (HCT) at IGEN/AFIP São Paulo and CHC/UFPR in Curitiba, Brazil
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, June 24, 2026, 12:00–1:00 PM ET
Hear an expert discuss the expanded clinical utility of HER2 IHC scoring in metastatic breast cancer and its impact on your practice
Webinar presenter Michelle Shiller, DO, AP, CP, MGP, FACP, Baylor University Medical Center.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Awareness Technology
ChemWell-T 4620
| Company | Awareness Technology |
|---|---|
| Name of instrument | ChemWell-T 4620 |
| City, State | Palm City, FL |
| Phone | 772-283-6540 |
| Website | |
| Type of instrument | chemistry |
| Operational type/Model type | batch, random access, discrete/benchtop |
| List price/First year sold in U.S. | $14, 000/2014 |
| Targeted hospital bed size/Targeted | 200/— |
| Company manufactures instrument | yes |
| Other models in this family of analyzers | ChemWell Fusion, ChemWell 2910, ChemWell 2902 |
| No. of units in clinical use in U.S./Outside U.S. (countries) | 200/4, 500 (worldwide) |
| Dimensions (H × W × D)/Instrument footprint | 20.87 × 19.69 × 18.5 in./2.853 sq. ft. |
| Weight empty/Weight fully loaded | 37 lbs./— |
| No. of different measured assays onboard simultaneously | 15 (12 can be run and calibrated at one time) |
| No. of user-definable (open chemistry) channels | — |
| Test throughput per hour/Assay run time | 100/— |
| No. of direct ion-selective electrode channels | — |
| Detection methods | photometry |
| • Ion-selective electrode | — |
| • Basic metabolic panel | assay dependent |
| • Complete metabolic panel | assay dependent |
| Typical time delay from ordering stat test until aspiration of sample | assay dependent |
| Fully automated microplate immunoassay system | — |
| Methodologies supported | — |
| Separation methodologies | — |
| Stat time until completion of a ß-hCG test | — |
| Stat time until completion of a cTn test | — |
| • Typical time delay from test order to aspiration of sample | — |
| Approximate No. of tests per reagent set/Reagent type | assay dependent/open reagent system |
| Reagents refrigerated onboard/Reagents ready to use | yes (8ϒ–15ϒC)/yes |
| Reagent lot tracking/Reagent inventory | yes/yes |
| Reagent form/Reagents barcoded | liquid chemistry (open reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/yes |
| Walkaway capability/Walkaway duration | yes/120 min. |
| Design of sample-handling system | rack (custom reagent and sample racks) |
| Uses washable cuvettes/Uses disposable cuvettes | yes/yes (can store up to 40 cuvettes) |
| Min.–max. sample volume that can be aspirated at one time | 2–388 µL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 240 µL/2 µL/40 µL |
| Dedicated pediatric sample cup | no |
| Primary tube sampling | yes |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | yes/yes (12 × 75 mm, 13 × 100 mm) |
| Pierces caps on primary tubes | no |
| Protects against probe collision | yes |
| Detects clots/liquid level/short sample | no/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | assay dependent |
| Dilutes patient samples onboard/Susceptibility to carryover | yes (can be programmed to perform dilutions prior to analysis)/no carryover |
| Automatic rerun capability | yes |
| Sample volume can be concentrated to rerun out-of-linear-range low results | yes |
| Analyzer requires dedicated water supply | no |
| Autocalibration/Multipoint calibration supported | no (calibrants can be stored onboard)/yes (recommended avg. frequency: test dependent) |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | — |
| Automatic programmable start/Automatic programmable shutdown | no/no |
| Onboard real-time QC/Onboard software capability to review QC | yes/yes |
| Supports multiple QC lot numbers per analyte | yes |
| Waste management | direct to drain |
| Sample barcode-reading capability/Autodiscrimination | yes (Code 39, Code 129)/no |
| Lab can control analyzer from remote computer | yes |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | yes |
| UPS backup power supply | no |
| Data-management capability/LIS or EHR systems interfaced | onboard/— |
| LIS interface provided/Bidirectional interface capability | yes/yes |
| Modem servicing provided/Service engineer on-site response time | no/72 hrs. |
| Mean time between failures | 1–2 service visits per year (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: 15 min. |
| Maintenance records kept onboard for user/vendor | no/no |
| Maintenance training demonstration module onboard | no |
| Training included with purchase/Avg. time for basic user training | yes (1 training slot)/2 days (at customer or vendor site) |
| Advanced operator training/Extra charge for follow-up or advanced training | yes (at customer or vendor site)/yes |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year from date of shipment)/contract dependent |
| Distinguishing features (supplied by company) | compact low-cost analyzer that saves on reagent use; open system; remote access; flexibility of hardware/software; software included (free) |