Webinars and Sponsored Roundtables — Register Now

Tuesday, April 28, 2026, 12:00 PM–1:00 PM ET
Discover how next-day comprehensive genomic profiling (CGP) is possible with the Oncomine Comprehensive Assay Plus on the Genexus System—delivering both speed and accuracy.

Webinar presenters Jane Bayani, MHSc, PhD, Assistant Professor and Co-Director, Diagnostic Development, Ontario Institute for Cancer Research, Canada, and Nicola Normanno, MD, Scientific Director, IRCCS Romagnolo Institute for the Study of Tumors, Italy, and Morten Grauslund, PhD, Molecular Biologist, Department of Pathology, Rigshospitalet/Copenhagen University Hospital, Copenhagen, Denmark.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Thermo Fisher Scientific. For Research Use Only. Not for use in diagnostic applications. 

Thursday, April 30, 2026, 11:00 AM–12:00 PM ET
Hear an expert discuss how Memorial Sloan Kettering Cancer Center (MSKCC) is utilizing
the oncoReveal® Nexus 21-gene panel to redefine turnaround time and actionable insights
in cancer care. Dr. Ewalt shares a perceptive look at the clinical need for rapid, front-line NGS sequencing, and how a unique, purpose built targeted NGS panel (Pillar Biosciences’ oncoReveal Nexus 21 gene Panel) was developed, validated and implemented clinically by Memorial Sloan Kettering Cancer Center (MSK-REACT) to complement their current comprehensive genomic profiling (CGP) approach.

Webinar presenter Mark Ewalt, MD, Associate Medical Director for Laboratory Operations for Diagnostic Molecular Pathology in the Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, MSKCC.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Pillar Biosciences.

Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.

Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Cente, and Colin Murphy,  CEO of mTuitive.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Gold Standard Diagnostics

Bolt

Company

Gold Standard Diagnostics

Name of instrument

Bolt

City, State

Davis, CA

Phone

530-759-8000  

Website

https://www.gsdx.us

Type of instrument

immunoassay

Operational type/Model type

batch/benchtop

List price/First year sold in U.S.

—/2016

Targeted hospital bed size/Targeted

Company manufactures instrument

yes (also sold by distribution partners)

Other models in this family of analyzers

Thunderbolt

No. of units in clinical use in U.S./Outside U.S. (countries)

Dimensions (H × W × D)/Instrument footprint

22 × 19 × 21 in./8 sq. ft.

Weight empty/Weight fully loaded

60 lbs./110 lbs.

No. of different measured assays onboard simultaneously

open EIA platform (up to 12 with limit of two washes, nine reagents and common incubation temperature, plate frame type)

No. of user-definable (open chemistry) channels

Test throughput per hour/Assay run time

assay dependent (96 tests in throughput)/20 min.–4 hr. (avg. 2 hr.)

No. of direct ion-selective electrode channels

Detection methods

• Ion-selective electrode

• Basic metabolic panel

• Complete metabolic panel

Typical time delay from ordering stat test until aspiration of sample

Fully automated microplate immunoassay system

yes (96 tests per unit; 96 wells per microplate)

Methodologies supported

chemiluminescence, enzyme immunoassay

Separation methodologies

coated microwell

Stat time until completion of a ß-hCG test

Stat time until completion of a cTn test

• Typical time delay from test order to aspiration of sample

Approximate No. of tests per reagent set/Reagent type

96/open reagent system

Reagents refrigerated onboard/Reagents ready to use

no (room temperature–40°C)/variable; reagent specific

Reagent lot tracking/Reagent inventory

yes/no

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/no

Separate reagent pack for each specimen/for each test run

no/yes

Walkaway capability/Walkaway duration

yes/avg. 120 min.

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

no/no

Min.–max. sample volume that can be aspirated at one time 

1–300 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

25 µL/151 µL/150 µL

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/no

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

no/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

hemolysis, icterus, lipemia, clots not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/assay specific

Automatic rerun capability

no

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Analyzer requires dedicated water supply

no

Autocalibration/Multipoint calibration supported

no (calibrants are not stored onboard)/yes (recommended avg. frequency: per batch)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/—/—/—/per batch

Automatic programmable start/Automatic programmable shutdown

no (5 min. start-up time)/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

manually by user

Sample barcode-reading capability/Autodiscrimination

yes (unspecified)/no

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

no

Data-management capability/LIS or EHR systems interfaced

onboard/—

LIS interface provided/Bidirectional interface capability

no/yes (host query) 

Modem servicing provided/Service engineer on-site response time

yes/48 hrs.

Mean time between failures

— (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 5 min.; weekly: 15 min.; monthly: 20 min.

Maintenance records kept onboard for user/vendor

yes (includes audit trail of who replaced parts)/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes (No. of training slots client dependent)/4 hrs. (at customer or vendor site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at customer or vendor site)/yes (client dependent)

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

open architecture: program any EIA or CLIA protocol, fully customizable with flexible, intuitive software; space saving: high capacity (96 samples) in 2 ft. × 2 ft. footprint; cost saving: low instrument price point with no routine consumables required