Webinars and Sponsored Roundtables — Register Now
Wednesday, September 30, 2026. 1 PM-1:30 PM ET
Roundtable presenters John Longshore, PhD, Head of Scientific Affairs, Global Oncology Diagnostics, AstraZeneca, and Flora Berisha, MS, Executive Director, Global Head of Diagnostic Partnering and Development, Johnson & Johnson Innovative Medicine, and Mark D. Ewalt, MD, Associate Medical Director for Laboratory Operations, Diagnostic Molecular Pathology, Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, and Isabel Preeshagul, DO, MBS, Thoracic Medical Oncologist, Memorial Sloan Kettering Cancer Center
CAP TODAY does not endorse any of the products or services named within. The roundtable is made possible by a special educational grant from Pillar Biosciences.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Thursday, October 1, 2026 1 PM-2 PM ET
This presentation will explore the value of in-house CGP, offer insights into the benefits and drawbacks of incorporation, and provide information about important practical factors when considering in-house implementation of CGP.
Webinar presenter Allison M. Cushman-Vokoun, MD, PhD, FCAP, Medical Director, Molecular Diagnostics and Personalized Medicine Laboratory, Director, Division of Diagnostic Molecular Pathology and Human Genetics, Henry F. Krous Professor of Pathology, University of Nebraska Medical Center
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Illumina.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, October 20, 2026 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.
Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, November 3, 2026 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.
Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Abbott Point of Care
i-STAT 1 analyzer
| Company | Abbott Point of Care |
|---|---|
| Name of instrument | i-STAT 1 analyzer |
| Contact | Jeff Abney |
| City, State | Princeton, NJ |
| Phone | 609-454-9000 |
| Website | |
| Type of instrument | combination chemistry/immunoassay |
| Operational type/Model type | discrete/handheld |
| List price/First year sold in U.S. | —/2000 |
| Targeted hospital bed size/Targeted test volume | all/— |
| Company manufactures instrument | yes (also sold by McKesson, Henry Schein, Medline, Cardinal, Concordance, others) |
| Other models in this family of analyzers | i-STAT Alinity |
| No. of units in clinical use in U.S./Outside U.S. (countries) | > 30,000/> 10,000 (Europe, Latin America, Africa, Middle East, Asia Pacific) |
| Dimensions (H × W × D)/Instrument footprint | 9.25 × 3 × 2.85 in./< 1 sq. ft. |
| Weight empty/Weight fully loaded | < 2 lbs./< 2 lbs. |
| No. of different measured assays onboard simultaneously | — |
| No. of user-definable (open chemistry) channels | — |
| Test throughput per hour/Assay run time | —/2–15 min. |
| No. of direct ion-selective electrode channels | up to 26 |
| Detection methods | potentiometry, amperometry, conductometry |
| Stat time until completion/specimen throughput for ion-selective electrode | 2 min./20–25 |
| Stat time until completion/specimen throughput for basic metabolic panel | 2 min./20–25 |
| Stat time until completion/specimen throughput for complete metabolic panel | — |
| Typical time delay from ordering stat test until aspiration of sample | none |
| Fully automated microplate immunoassay system | yes (up to 26 tests per unit) |
| Methodologies supported | potentiometry, amperometry, conductometry |
| Separation methodologies | none necessary |
| Stat time until completion of a ß-hCG test | — |
| Stat time until completion of a cTn test | 10 min. |
| • Typical time delay from test order to aspiration of sample | none |
| Approximate No. of tests per reagent set/Reagent type | —/self-contained single use |
| Reagents refrigerated onboard/Reagents ready to use | no/— |
| Reagent lot tracking/Reagent inventory | no/no |
| Reagent form/Reagents barcoded | dry chemistry, liquid chemistry (closed reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/no |
| Walkaway capability/Walkaway duration | yes/2–10 min. or 1 specimen or up to 13 tests |
| Design of sample-handling system | — |
| Uses washable cuvettes/Uses disposable cuvettes | no/no |
| Min.–max. sample volume that can be aspirated at one time | 17–95 µL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | — |
| Dedicated pediatric sample cup | no |
| Primary tube sampling | no |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | no/no |
| Pierces caps on primary tubes | no |
| Protects against probe collision | no |
| Detects clots/liquid level/short sample | yes/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | detection for hemolysis, icterus, lipemia, clots |
| Dilutes patient samples onboard/Susceptibility to carryover | no/— |
| Automatic rerun capability | no |
| Sample volume can be diluted to rerun out-of-linear-range high results | no |
| Sample volume can be concentrated to rerun out-of-linear-range low results | no |
| Autocalibration/Multipoint calibration supported | yes (calibrants are not stored onboard)/yes (recommended avg. frequency: each test) |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | —/—/—/each test/each test |
| Automatic programmable start/Automatic programmable shutdown | yes/yes |
| Onboard real-time QC/Onboard software capability to review QC | yes/yes |
| Supports multiple QC lot numbers per analyte | yes |
| Waste management | manually by user |
| Sample barcode-reading capability/Autodiscrimination | yes (Interleaved 2 of 5, Codabar, Code 39, Code 128, EAN-8, EAN-13)/— |
| Lab can control analyzer from remote computer | yes |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | yes |
| UPS backup power supply | no |
| Data-management capability/LIS or EHR systems interfaced | optional add-on/— |
| LIS interface provided/Bidirectional interface capability | yes (additional cost)/no |
| Modem servicing provided/Service engineer on-site response time | —/— (product replacement within 24 hrs.) |
| Mean time between failures | — (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | — |
| Maintenance records kept onboard for user/vendor | — |
| Maintenance training demonstration module onboard | — |
| Training included with purchase/Avg. time for basic user training | —/4 hrs. (at customer site) |
| Advanced operator training/Extra charge for follow-up or advanced training | yes (at customer site)/no |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year)/— |
| Distinguishing features (supplied by company) | handheld portable analyzer; unit use system can perform chemistry, blood gas, cardiac marker, hematology, and coagulation tests; CLIA-waived tests, including glucose and creatinine; uses 2–3 drops of whole blood or plasma |
| Note | all information listed was provided to CAP TODAY in 2025; company did not provide updated information by 2026 entry deadline |