Webinars and Sponsored Roundtables — Register Now

Tuesday, April 28, 2026, 12:00 PM–1:00 PM ET
Discover how next-day comprehensive genomic profiling (CGP) is possible with the Oncomine Comprehensive Assay Plus on the Genexus System—delivering both speed and accuracy.

Webinar presenters Jane Bayani, MHSc, PhD, Assistant Professor and Co-Director, Diagnostic Development, Ontario Institute for Cancer Research, Canada, and Nicola Normanno, MD, Scientific Director, IRCCS Romagnolo Institute for the Study of Tumors, Italy, and Morten Grauslund, PhD, Molecular Biologist, Department of Pathology, Rigshospitalet/Copenhagen University Hospital, Copenhagen, Denmark.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Thermo Fisher Scientific. For Research Use Only. Not for use in diagnostic applications. 

Thursday, April 30, 2026, 11:00 AM–12:00 PM ET
Hear an expert discuss how Memorial Sloan Kettering Cancer Center (MSKCC) is utilizing
the oncoReveal® Nexus 21-gene panel to redefine turnaround time and actionable insights
in cancer care. Dr. Ewalt shares a perceptive look at the clinical need for rapid, front-line NGS sequencing, and how a unique, purpose built targeted NGS panel (Pillar Biosciences’ oncoReveal Nexus 21 gene Panel) was developed, validated and implemented clinically by Memorial Sloan Kettering Cancer Center (MSK-REACT) to complement their current comprehensive genomic profiling (CGP) approach.

Webinar presenter Mark Ewalt, MD, Associate Medical Director for Laboratory Operations for Diagnostic Molecular Pathology in the Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, MSKCC.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Pillar Biosciences.

Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.

Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Cente, and Colin Murphy,  CEO of mTuitive.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Beckman Coulter

DxC 500 AU Clinical Chemistry Analyzer

Company

Beckman Coulter

Name of instrument

DxC 500 AU Clinical Chemistry Analyzer

City, State

Brea, CA

Phone

800-526-3821

Website

https://www.beckmancoulter.com

Type of instrument

chemistry

Operational type/Model type

continuous random access/floor standing

List price/First year sold in U.S.

—/2024

Targeted hospital bed size/Targeted

—/annual: 50, 000–350, 000

Company manufactures instrument

yes (also sold by distribution partners)

Other models in this family of analyzers

DxC 700 AU, AU5800

No. of units in clinical use in U.S./Outside U.S. (countries)

Nov-00

Dimensions (H × W × D)/Instrument footprint

48 × 61 × 31 in./52.1 sq. ft.

Weight empty/Weight fully loaded

—/maximum 992 lbs.

No. of different measured assays onboard simultaneously

63 (60 plus 3 ISE can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

18

Test throughput per hour/Assay run time

up to 800: 400 photometric, 400 ISE/< 9 min.

No. of direct ion-selective electrode channels

3 indirect

Detection methods

photometry, potentiometry

• Ion-selective electrode

• Basic metabolic panel

• Complete metabolic panel

Typical time delay from ordering stat test until aspiration of sample

Fully automated microplate immunoassay system

Methodologies supported

Separation methodologies

Stat time until completion of a ß-hCG test

Stat time until completion of a cTn test

• Typical time delay from test order to aspiration of sample

Approximate No. of tests per reagent set/Reagent type

—/self-contained single use

Reagents refrigerated onboard/Reagents ready to use

yes (4.5°–12°C)/variable; reagent specific

Reagent lot tracking/Reagent inventory

yes/no

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/168 specimens

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

yes (can store up to 88 cuvettes)/no

Min.–max. sample volume that can be aspirated at one time 

1–25 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

90 µL/50 µL/80 µL

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/—

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for hemolysis, icterus, lipemia, clots

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/—

Automatic rerun capability

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Analyzer requires dedicated water supply

yes (20 L/hr. consumption during operation)

Autocalibration/Multipoint calibration supported

yes (calibrants are not stored onboard)/yes

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

1 day/—/—/1–90 days/—

Automatic programmable start/Automatic programmable shutdown

no/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

Waste management

direct to drain

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Code 39, Code 128, NW7, EAN-13, ISBT-128, Standard 2 of 5)/—

Lab can control analyzer from remote computer

yes

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/Medicus, Orchard, Evident, CGM LabDaq, Cerner, Sunquest

LIS interface provided/Bidirectional interface capability

no/yes (host query)

Modem servicing provided/Service engineer on-site response time

Mean time between failures

Average scheduled maintenance time by lab personnel

daily: 4 min.; weekly: 10 min.; monthly: 45 min.

Maintenance records kept onboard for user/vendor

yes/no

Maintenance training demonstration module onboard

yes

Training included with purchase/Avg. time for basic user training

yes (2 training slots)/—

Advanced operator training/Extra charge for follow-up or advanced training

yes (at vendor site)/—

Warranty provided/Cost of annual service contract (24 h/7 d)

Distinguishing features (supplied by company)

intuitive user interface with user-friendly software that guides workflow and anticipates laboratory needs; commonly replaced parts can be changed in 3 steps, in 60 seconds, and without tools; standardization across the AU family of chemistry analyzers