Webinars and Sponsored Roundtables — Register Now

Tuesday, April 28, 2026, 12:00 PM–1:00 PM ET
Discover how next-day comprehensive genomic profiling (CGP) is possible with the Oncomine Comprehensive Assay Plus on the Genexus System—delivering both speed and accuracy.

Webinar presenters Jane Bayani, MHSc, PhD, Assistant Professor and Co-Director, Diagnostic Development, Ontario Institute for Cancer Research, Canada, and Nicola Normanno, MD, Scientific Director, IRCCS Romagnolo Institute for the Study of Tumors, Italy, and Morten Grauslund, PhD, Molecular Biologist, Department of Pathology, Rigshospitalet/Copenhagen University Hospital, Copenhagen, Denmark.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Thermo Fisher Scientific. For Research Use Only. Not for use in diagnostic applications. 

Thursday, April 30, 2026, 11:00 AM–12:00 PM ET
Hear an expert discuss how Memorial Sloan Kettering Cancer Center (MSKCC) is utilizing
the oncoReveal® Nexus 21-gene panel to redefine turnaround time and actionable insights
in cancer care. Dr. Ewalt shares a perceptive look at the clinical need for rapid, front-line NGS sequencing, and how a unique, purpose built targeted NGS panel (Pillar Biosciences’ oncoReveal Nexus 21 gene Panel) was developed, validated and implemented clinically by Memorial Sloan Kettering Cancer Center (MSK-REACT) to complement their current comprehensive genomic profiling (CGP) approach.

Webinar presenter Mark Ewalt, MD, Associate Medical Director for Laboratory Operations for Diagnostic Molecular Pathology in the Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, MSKCC.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Pillar Biosciences.

Thursday, May 28, 2026, 1:00–2:00 PM ET
This session is designed to improve understanding and application of recent updates to synoptic pathology reporting protocols such as the latest Reporting Template for Reporting Results of Biomarker Testing of Specimens from Patients with Carcinoma of the Breast. These changes reflect evolving clinical guidelines that directly influence diagnostic accuracy and treatment selection in breast cancer care.

Webinar presenters Thaer Khoury, MD, FCAP, Chair, Pathology and Laboratory Medicine, Roswell Park Comprehensive Cancer Cente, and Colin Murphy,  CEO of mTuitive.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Tosoh Bioscience

AIA-360

Company

Tosoh Bioscience

Name of instrument

AIA-360

City, State

Grove City, OH

Phone

800-248-6764

Website

https://www.diagnostics.us.tosohbioscience.com

Type of instrument

immunoassay

Operational type/Model type

continuous random access/benchtop

List price/First year sold in U.S.

—/2004

Targeted hospital bed size/Targeted

—/monthly: < 500

Company manufactures instrument

yes

Other models in this family of analyzers

AIA-900, AIA-2000

No. of units in clinical use in U.S./Outside U.S. (countries)

~600/> 7, 000 (worldwide)

Dimensions (H × W × D)/Instrument footprint

21 × 16 × 16 in./2.1 sq. ft.

Weight empty/Weight fully loaded

61 lbs./—

No. of different measured assays onboard simultaneously

25 (25 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

Test throughput per hour/Assay run time

36/10 min.

No. of direct ion-selective electrode channels

Detection methods

• Ion-selective electrode

• Basic metabolic panel

• Complete metabolic panel

Typical time delay from ordering stat test until aspiration of sample

Fully automated microplate immunoassay system

Methodologies supported

fluorescence

Separation methodologies

Stat time until completion of a ß-hCG test

20 min.

Stat time until completion of a cTn test

20 min.

• Typical time delay from test order to aspiration of sample

Approximate No. of tests per reagent set/Reagent type

100 (20 tests per tray)/unit dose test cup

Reagents refrigerated onboard/Reagents ready to use

no/yes

Reagent lot tracking/Reagent inventory

yes/no

Reagent form/Reagents barcoded

dry chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

yes/—

Walkaway capability/Walkaway duration

yes/58 min. or 25 specimens or 25 tests/assays

Design of sample-handling system

carousel

Uses washable cuvettes/Uses disposable cuvettes

no/no

Min.–max. sample volume that can be aspirated at one time 

10–100 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

10 µL/110 µL/100 µL

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/—

Pierces caps on primary tubes

no

Protects against probe collision

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

Dilutes patient samples onboard/Susceptibility to carryover

no/none

Automatic rerun capability

no

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Analyzer requires dedicated water supply

no

Autocalibration/Multipoint calibration supported

no (calibrants are not stored onboard)/yes

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/—/—/—/90 days most assays

Automatic programmable start/Automatic programmable shutdown

no (5 min. start-up time)/no

Onboard real-time QC/Onboard software capability to review QC

no/no

Supports multiple QC lot numbers per analyte

Waste management

automated collection onboard instrument

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

no

System malfunctions can be diagnosed via remote monitoring

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

Tosoh 501RP+/—

LIS interface provided/Bidirectional interface capability

no/no

Modem servicing provided/Service engineer on-site response time

Mean time between failures

888 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 5 min.

Maintenance records kept onboard for user/vendor

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes/2 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

unit dose test cup; dry reagent, no premixing or reagent preparation; immunoassay method free from biotin interference; compact size, broad menu with fast results; 90-day calibration stability for most assays

More products
in this guide

DxC 500 AU Clinical Chemistry Analyzer
DxC 500i Clinical Analyzer
Pictus 500 (P500)
DS2 Automated ELISA System
Stat Profile Prime Plus
Vitros XT 3400 Chemistry Systems
cobas pure integrated solutions
B⋅R⋅A⋅H⋅M⋅S KRYPTOR compact PLUS