Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Dynex Technologies

DS2 Elite Automated ELISA System

Company

Dynex Technologies

Name of instrument

DS2 Elite Automated ELISA System

Contact

Global Customer Service  

Email

customerservice@dynex.com

City, State

Chantilly, VA

Phone

800-288-2354  

Website

https://www.dynex.com

Type of instrument

immunoassay

Operational type/Model type

batch/benchtop

List price/First year sold in U.S.

—/2007

Targeted hospital bed size/Targeted test volume

—/daily: < 4 microplates (96-well microplates)

Company manufactures instrument

yes

Other models in this family of analyzers

DSX

No. of units in clinical use in U.S./Outside U.S. (countries)

—/4,510 (worldwide)

Dimensions (H × W × D)/Instrument footprint

26.25 × 21 × 27.5 in./3.9 sq. ft.

Weight empty/Weight fully loaded

105 lbs./—

No. of different measured assays onboard simultaneously

up to 12 assays per microplate (up to 12 can be run)

No. of user-definable (open chemistry) channels

— (open system; up to 12 can be active simultaneously)

Test throughput per hour/Assay run time

assay dependent (up to 384 tests per run)/assay dependent

No. of direct ion-selective electrode channels

—

Detection methods

—

Stat time until completion/specimen throughput for ion-selective electrode

—

Stat time until completion/specimen throughput for basic metabolic panel

—

Stat time until completion/specimen throughput for complete metabolic panel

—

Typical time delay from ordering stat test until aspiration of sample

—

Fully automated microplate immunoassay system

yes (up to 12 tests per unit; 96 wells per microplate)

Methodologies supported

enzyme immunoassay

Separation methodologies

coated microwell

Stat time until completion of a ß-hCG test

—

Stat time until completion of a cTn test

—

• Typical time delay from test order to aspiration of sample

—

Approximate No. of tests per reagent set/Reagent type

—/open reagent system

Reagents refrigerated onboard/Reagents ready to use

no (23°±4°C)/—

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/yes

Walkaway capability/Walkaway duration

yes/up to 192 specimens or up to 192 tests/assays

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

no/—

Min.–max. sample volume that can be aspirated at one time 

10–250 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

10 µL/—/—

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes (17 × 100 mm)

Pierces caps on primary tubes

no

Protects against probe collision

no

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for clots; hemolysis, icterus, lipemia not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/0 parts per million

Automatic rerun capability

no

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Autocalibration/Multipoint calibration supported

no (calibrants are not stored onboard)/yes (recommended avg. frequency: assay dependent)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/assay dependent/assay dependent/—/assay dependent

Automatic programmable start/Automatic programmable shutdown

no/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

automated collection onboard instrument

Sample barcode-reading capability/Autodiscrimination

yes (UPC, Codabar, Code 39, Code 128, Code 93)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/Clinisys, Oracle Health

LIS interface provided/Bidirectional interface capability

no/yes (host query)

Modem servicing provided/Service engineer on-site response time

no/24 hrs.

Mean time between failures

250 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 10 min.; weekly: 5 min.

Maintenance records kept onboard for user/vendor

no/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

no/3 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at customer site)/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

run any assay from any vendor–fully automated open system; reliable workload scheduling–more than 98 percent mean time between failures; saves space–less than 4 sq. ft. of linear counter space to process up to two 96-well microplates and 100 specimens

More products
in this guide

DxC 500 AU Clinical Chemistry Analyzer
DxC 500i Clinical Analyzer
Pictus 500 (P500)
Stat Profile Prime Plus
VITROS XT 3400 Chemistry Systems
cobas pure integrated solutions 
B⋅R⋅A⋅H⋅M⋅S KRYPTOR compact PLUS