Webinars and Sponsored Roundtables — Register Now

Tuesday, July 21, 2026, 11:00-11:30 AM CT

Learning Objectives:
  • Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
  • Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
  • Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.

Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.

Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

HORIBA

Pentra C400

Company

HORIBA

Name of instrument

Pentra C400

Contact

Susan Behnke  

Email

medical-marketing.us@horiba.com

City, State

Irvine, CA

Phone

888-903-5001  

Website

https://www.horiba.com/us/en/medical/

Type of instrument

chemistry

Operational type/Model type

batch, random access, continuous random access, discrete/benchtop

List price/First year sold in U.S.

$100,000/2006

Targeted hospital bed size/Targeted test volume

≤ 250/daily: 1,200; monthly: 24,000; annual: 288,000

Company manufactures instrument

yes (also sold by distribution partners)

Other models in this family of analyzers

Pentra 400, Pentra C200

No. of units in clinical use in U.S./Outside U.S. (countries)

650/ 1,900

Dimensions (H × W × D)/Instrument footprint

25 × 40 × 28 in./7.7 sq. ft.

Weight empty/Weight fully loaded

264 lbs./266 lbs.

No. of different measured assays onboard simultaneously

55 (55 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

40 (40 can be active simultaneously)

Test throughput per hour/Assay run time

420 (4 tests in throughput)/1–10 min. (avg. 5 min.)

No. of direct ion-selective electrode channels

3

Detection methods

photometry, potentiometry, enzyme immunoassay immunoturbidimetry

Stat time until completion/specimen throughput for ion-selective electrode

< 5 min./37 specimens per hr.

Stat time until completion/specimen throughput for basic metabolic panel

7.5 min./35 specimens per hr.

Stat time until completion/specimen throughput for complete metabolic panel

< 11 min./23 specimens per hr.

Typical time delay from ordering stat test until aspiration of sample

< 1 min.

Fully automated microplate immunoassay system

Methodologies supported

Separation methodologies

Stat time until completion of a ß-hCG test

Stat time until completion of a cTn test

• Typical time delay from test order to aspiration of sample

Approximate No. of tests per reagent set/Reagent type

100–400/self-contained multiuse, open reagent system

Reagents refrigerated onboard/Reagents ready to use

yes (2°–8°C)/variable; reagent specific

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/180 min. or 60 specimens or > 800 tests/assays

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

no/yes (can store up to 432 cuvettes)

Min.–max. sample volume that can be aspirated at one time 

2–60 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

180 µL/2 µL/100 µL

Dedicated pediatric sample cup

yes (dead volume: 100 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for clots; hemolysis, icterus, lipemia not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/—

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Autocalibration/Multipoint calibration supported

yes (calibrants can be stored onboard)/yes (recommended avg. frequency: 14 days)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

2 hrs. (automatic)/—/—/avg. 14 days/—

Automatic programmable start/Automatic programmable shutdown

yes (5 min. start-up time)/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

no

Waste management

direct to drain or container if no drain available

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

no

Data-management capability/LIS or EHR systems interfaced

onboard/CGM LabDaq, Clinisys, Oracle Health, Meditech, Schuyler House

LIS interface provided/Bidirectional interface capability

no/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

no/< 24 hrs.

Mean time between failures

avg. 250 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: < 5 min.; weekly: < 15 min.; monthly: < 30 min.

Maintenance records kept onboard for user/vendor

yes (includes audit trail of who replaced parts)/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes/2.5 days (at customer or vendor site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at vendor site)/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

full menu of moderately complex drugs of abuse and general chemistry assays; can run up to 55 assays onboard with 420 results/hr.; no requirement for external water system, no drain or special electrical required; remote diagnostics available for real-time troubleshooting; flexible, open-channel system capable of running ″ 40 third-party reagents onboard

More products
in this guide

DxC 500 AU Clinical Chemistry Analyzer
DxC 500i Clinical Analyzer
Pictus 500 (P500)
DS2 Elite Automated ELISA System
Stat Profile Prime Plus
VITROS XT 3400 Chemistry Systems
cobas pure integrated solutions 
B⋅R⋅A⋅H⋅M⋅S KRYPTOR compact PLUS