Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Nova Biomedical

Stat Profile Prime Plus

Company

Nova Biomedical

Name of instrument

Stat Profile Prime Plus

Email

info@novabio.com

City, State

Waltham, MA

Phone

800-458-5813  

Website

https://www.novabiomedical.com

Type of instrument

chemistry

Operational type/Model type

random access/benchtop

List price/First year sold in U.S.

—/2018

Targeted hospital bed size/Targeted test volume

—

Company manufactures instrument

yes (also sold by distribution partners)

Other models in this family of analyzers

Stat Profile Prime CCS, Stat Profile Prime, Stat Profile Prime ES

No. of units in clinical use in U.S./Outside U.S. (countries)

—

Dimensions (H × W × D)/Instrument footprint

18 × 14 × 16 in./1.5 sq. ft. 

Weight empty/Weight fully loaded

35 lbs./42 lbs.

No. of different measured assays onboard simultaneously

20 (20 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

30 (30 can be active simultaneously)

Test throughput per hour/Assay run time

up to 38 (760 tests in throughput)/avg. 90 sec.

No. of direct ion-selective electrode channels

7

Detection methods

photometry, potentiometry, Severinghaus, amperometry, conductivity, enzyme

Stat time until completion/specimen throughput for ion-selective electrode

90 sec./38 specimens per hr.

Stat time until completion/specimen throughput for basic metabolic panel

90 sec./38 specimens per hr.

Stat time until completion/specimen throughput for complete metabolic panel

90 sec./38 specimens per hr.

Typical time delay from ordering stat test until aspiration of sample

3 sec.

Fully automated microplate immunoassay system

—

Methodologies supported

—

Separation methodologies

—

Stat time until completion of a ß-hCG test

—

Stat time until completion of a cTn test

—

• Typical time delay from test order to aspiration of sample

—

Approximate No. of tests per reagent set/Reagent type

100, 200, 300, 400, or 500/self-contained multiuse

Reagents refrigerated onboard/Reagents ready to use

no/yes

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/1 min. or 1 specimen or 20 tests/assays

Design of sample-handling system

probe

Uses washable cuvettes/Uses disposable cuvettes

no/yes

Min.–max. sample volume that can be aspirated at one time 

90–135 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

135 µL/135 µL/—

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for hemolysis, clots

Dilutes patient samples onboard/Susceptibility to carryover

no/—

Automatic rerun capability

no

Sample volume can be diluted to rerun out-of-linear-range high results

no

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Autocalibration/Multipoint calibration supported

yes (calibrants can be stored onboard)/yes

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—

Automatic programmable start/Automatic programmable shutdown

yes (5 min. avg. start-up time)/yes

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

automated collection onboard instrument

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

yes

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes (optional)

Data-management capability/LIS or EHR systems interfaced

onboard, optional add-on (NovaNet, more)/—

LIS interface provided/Bidirectional interface capability

yes (included in instrument price)/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

no/within 8 hrs.

Mean time between failures

— (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

—

Maintenance records kept onboard for user/vendor

yes/yes (both include audit trail of who replaced parts)

Maintenance training demonstration module onboard

yes

Training included with purchase/Avg. time for basic user training

yes/30 min. (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes/no

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (5 years)/—

Distinguishing features (supplied by company)

maintenance-free MicroSensor Card and disposable cartridge technology for sensors and reagents; broad menu including iMg, BUN, creatinine/eGFR CO-oximetry, estimated plasma volume; automated, liquid QC and supplemental quality monitoring for EP23-A compliance and real-time verification of all analytical components during calibration, sample analysis, QC analysis

Note

all information listed was provided to CAP TODAY in 2025; company did not provide updated information by 2026 entry deadline