Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Roche Diagnostics

cobas e 411

Company

Roche Diagnostics

Name of instrument

cobas e 411

Contact

Brianna Frederick  

Email

brianna.frederick@roche.com

City, State

Indianapolis, IN

Phone

800-428-5074  

Website

https://diagnostics.roche.com/us/en/home.html

Type of instrument

immunoassay

Operational type/Model type

random access, continuous random access/benchtop

List price/First year sold in U.S.

—/2008

Targeted hospital bed size/Targeted test volume

< 100/daily: < 200; monthly: < 40,000; annual: < 500,000

Company manufactures instrument

no (manufactured by Hitachi High-Technologies)

Other models in this family of analyzers

—

No. of units in clinical use in U.S./Outside U.S. (countries)

> 800/> 10,000 (> 50 countries)

Dimensions (H × W × D)/Instrument footprint

disk: 31.4 × 47.2 × 28.7 in./9.4 sq. ft.; rack: 31.4 × 67 × 37.4 in./17.4 sq. ft. 

Weight empty/Weight fully loaded

disk: 397 lbs./397 lbs.; rack: 551 lbs./551 lbs.

No. of different measured assays onboard simultaneously

18 (18 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

0

Test throughput per hour/Assay run time

86 (86 tests in throughput)/9–27 min. (avg. 18 min.)

No. of direct ion-selective electrode channels

—

Detection methods

—

Stat time until completion/specimen throughput for ion-selective electrode

—

Stat time until completion/specimen throughput for basic metabolic panel

—

Stat time until completion/specimen throughput for complete metabolic panel

—

Typical time delay from ordering stat test until aspiration of sample

—

Fully automated microplate immunoassay system

no

Methodologies supported

electrochemiluminescence

Separation methodologies

magnetic particle

Stat time until completion of a ß-hCG test

~10 min. 

Stat time until completion of a cTn test

~10 min.

• Typical time delay from test order to aspiration of sample

< 1 min.

Approximate No. of tests per reagent set/Reagent type

100–200/self-contained multiuse

Reagents refrigerated onboard/Reagents ready to use

no (20° ±3°C)/yes

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/30–60 min. or 30 specimens (disk), 75 specimens (rack) or 2,000–3,000 tests/assays

Design of sample-handling system

disk: ring; rack: rack

Uses washable cuvettes/Uses disposable cuvettes

no/yes (can store up to 360 assay tips, 180 assay cups)

Min.–max. sample volume that can be aspirated at one time 

10–50 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

100 µL/10 µL/100 µL

Dedicated pediatric sample cup

yes (dead volume: 50 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes (12 × 100 mm)

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for clots; hemolysis, icterus, lipemia not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform sample dilutions prior to analysis)/0 (uses disposable tips)

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Autocalibration/Multipoint calibration supported

yes (calibrants are not stored onboard)/yes (recommended avg. frequency: 28 days)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/—/—/—/28 days

Automatic programmable start/Automatic programmable shutdown

yes (4 min. avg. start-up time)/yes

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

automated collection onboard instrument

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Codabar, Code 39, Code 128, PDF417)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/SCC Soft Computer, Meditech, Oracle Health, Epic, Clinisys, more

LIS interface provided/Bidirectional interface capability

yes (included in instrument price)/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

yes/< 24 hrs.

Mean time between failures

368 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 5 min.; weekly: 6 min.; monthly: 11 min.

Maintenance records kept onboard for user/vendor

some records/some records

Maintenance training demonstration module onboard

yes

Training included with purchase/Avg. time for basic user training

yes (1 training slot)/1 week (at both vendor and customer sites)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at vendor site)/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/configuration dependent

Distinguishing features (supplied by company)

drives lab efficiency with standardized instrumentation, reference ranges, consumables, and usage; minimizes downtime with industry-leading engineering and service; 325-day mean time between repair visits (average); speeds up turnaround time for high-volume stat assays

More products
in this guide

DxC 500 AU Clinical Chemistry Analyzer
DxC 500i Clinical Analyzer
Pictus 500 (P500)
DS2 Elite Automated ELISA System
Stat Profile Prime Plus
VITROS XT 3400 Chemistry Systems
cobas pure integrated solutions 
B⋅R⋅A⋅H⋅M⋅S KRYPTOR compact PLUS