Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Tosoh Bioscience

AIA-360

Company

Tosoh Bioscience

Name of instrument

AIA-360

Email

info.diag.am@tosoh.com

City, State

Grove City, OH

Phone

800-248-6764  

Website

https://www.diagnostics.us.tosohbioscience.com

Type of instrument

immunoassay

Operational type/Model type

continuous random access/benchtop

List price/First year sold in U.S.

—/2004

Targeted hospital bed size/Targeted test volume

—/monthly: < 500

Company manufactures instrument

yes

Other models in this family of analyzers

AIA-900, AIA-2000

No. of units in clinical use in U.S./Outside U.S. (countries)

~600/> 7,000 (worldwide)

Dimensions (H × W × D)/Instrument footprint

21 × 16 × 16 in./2.1 sq. ft.

Weight empty/Weight fully loaded

61 lbs./—

No. of different measured assays onboard simultaneously

25 (25 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

—

Test throughput per hour/Assay run time

36/20 min.

No. of direct ion-selective electrode channels

—

Detection methods

—

Stat time until completion/specimen throughput for ion-selective electrode

—

Stat time until completion/specimen throughput for basic metabolic panel

—

Stat time until completion/specimen throughput for complete metabolic panel

—

Typical time delay from ordering stat test until aspiration of sample

—

Fully automated microplate immunoassay system

—

Methodologies supported

fluorescence enzyme immunoassay (FEIA)

Separation methodologies

—

Stat time until completion of a ß-hCG test

20 min.

Stat time until completion of a cTn test

20 min.

• Typical time delay from test order to aspiration of sample

—

Approximate No. of tests per reagent set/Reagent type

100 (20 tests per tray)/unit dose test cup

Reagents refrigerated onboard/Reagents ready to use

no/yes

Reagent lot tracking/Reagent inventory

yes/no

Reagent form/Reagents barcoded

dry chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

yes/—

Walkaway capability/Walkaway duration

yes/58 min. or 25 specimens or 25 tests/assays

Design of sample-handling system

carousel

Uses washable cuvettes/Uses disposable cuvettes

no/no

Min.–max. sample volume that can be aspirated at one time 

10–100 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

10 µL/110 µL/100 µL

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/—

Pierces caps on primary tubes

no

Protects against probe collision

—

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

—

Dilutes patient samples onboard/Susceptibility to carryover

no/none

Automatic rerun capability

no

Sample volume can be diluted to rerun out-of-linear-range high results

no

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Autocalibration/Multipoint calibration supported

no (calibrants are not stored onboard)/yes

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/—/—/—/90 days most assays

Automatic programmable start/Automatic programmable shutdown

no (5 min. start-up time)/no

Onboard real-time QC/Onboard software capability to review QC

no/no

Supports multiple QC lot numbers per analyte

—

Waste management

automated collection onboard instrument

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

no

System malfunctions can be diagnosed via remote monitoring

—

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

Tosoh 501RP+/—

LIS interface provided/Bidirectional interface capability

no/no

Modem servicing provided/Service engineer on-site response time

—

Mean time between failures

888 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 5 min.

Maintenance records kept onboard for user/vendor

no/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes/2 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

—

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

unit dose test cup; dry reagent, no premixing or reagent preparation; immunoassay method free from biotin interference; compact size, broad menu with fast results; 90-day calibration stability for most assays