Webinars and Sponsored Roundtables — Register Now

Wednesday, September 30, 2026. 1 PM-1:30 PM ET
Roundtable presenters John Longshore, PhD, Head of Scientific Affairs, Global Oncology Diagnostics, AstraZeneca, and Flora Berisha, MS, Executive Director, Global Head of Diagnostic Partnering and Development, Johnson & Johnson Innovative Medicine, and Mark D. Ewalt, MD, Associate Medical Director for Laboratory Operations, Diagnostic Molecular Pathology, Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, and Isabel Preeshagul, DO, MBS, Thoracic Medical Oncologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The roundtable is made possible by a special educational grant from Pillar Biosciences.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 1, 2026 1 PM-2 PM ET
This presentation will explore the value of in-house CGP, offer insights into the benefits and drawbacks of incorporation, and provide information about important practical factors when considering in-house implementation of CGP.

Webinar presenter Allison M. Cushman-Vokoun, MD, PhD, FCAP, Medical Director, Molecular Diagnostics and Personalized Medicine Laboratory, Director, Division of Diagnostic Molecular Pathology and Human Genetics, Henry F. Krous Professor of Pathology, University of Nebraska Medical Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Illumina.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, October 20, 2026 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Advanced Instruments

GloCyte Automated Cell Counter for CSF

Company

Advanced Instruments

Name of analyzer

GloCyte Automated Cell Counter for CSF

Contact

Maria Martinek

Email

maria.martinek@aicompanies.com

City, State

Norwood, MA

Phone

800-225-4034  

Website

https://www.aicompanies.com

Analyzer application

diagnostic and research use

Dimensions of analyzer (H × W ×

10.0 × 6.0 × 8.0 in./—

Country where analyzer was

U.S./U.S.

First year analyzer was sold in U.S./Approximate No. of units installed in U.S.*

2016/200

First year analyzer sold outside

—

Foreign locations where company

U.K. (installed in U.K.)

Human languages (other than

—

Analyzer list price

—

• Analyzer acquisition options

purchase

Training included with purchase/Total time for basic training per operator

—

• Follow-up training available

yes

Parameters that analyzer tests and reports

—

Types of testing FDA cleared or approved for analyzer

—

Types of body fluids FDA cleared or approved for analysis on analyzer

CSF

Analytical measurement range for body fluid

RBC count: 2–123 cells/µL (reportable range, 2–615, 644 cells/µL); TNC count: 3–123 cells/µL (reportable range, 3–6, 500 cells/µL)

Precision for body fluid

RBC count: 2.7–16.3%; TNC count: 2.5–18%

Accuracy for body fluid

—

Automated differential performed for body fluids

—

Tests available for research use only

—

Differential methods used

—

Analytical measurement range: • WBC count/RBC count

WBC: — (TNC: 3–6, 500 cells/µL)/RBC: 2–123 cells/µL (reportable range, 2–615, 644 cells/µL)

Precision: • WBC count/RBC count

—

Accuracy: • WBC count/RBC count

—

Interfering substances: • WBC/RBC

—

• Hemoglobin/Platelets

—

• Hematocrit/Reticulocytes

—

• Automated differential

—

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

—

• Max. No. of slides processed per hour if stainer included

—

FDA-cleared or -approved sample container types (besides potassium EDTA)

—

Min. specimen volume open mode/Closed mode/Microsample capability

60 µL/—/no

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

sample type, sample appearance, sample color, accession number, result/>100, 000 results

Analyzer performs delta checks

no

Parameters for which flags may appear

control results out of range, expired reagents warning

Analyzer recognizes and holds test results

yes, for potential test rerun (parameters for flags to hold samples defined by vendor)

Scattergram display uses cell-specific color

no

Histogram display uses color with thresholds

no

LIS interface formats supported

RS232, bidirectional

• Middleware interface

no (connects directly to LIS)

• Information transferred to LIS via middleware or LIS interface

numeric results, flagged results, patient orders

Analyzer transmits LOINC codes for results to LIS or middleware

yes

Lab automation system or workcells to which analyzer has a direct interface

none

Barcode symbologies read on specimen tube

Codabar, Data Matrix, Code 39, Code 128

• Analyzer allows barcode placement per CLSI standard Auto02-A2

yes (also supports QR codes)

No. of onboard reagents required for standard specimen analysis

2

• Reagents ready to use/Reagent tracking method

yes/RFID, barcode reader

Onboard diagnostics for troubleshooting

yes

• Manufacturer can perform diagnostics via remote access

no

Warranty provided/Cost of annual service contract (24 h/7 d)

one-year warranty/—

Notes

—

More products
in this guide

Alinity h-series
CELL-DYN Emerald†
CELL-DYN Emerald 22
CELL-DYN Emerald 22 Autoloader
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 690T Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series† (XN-1000, XN-2000, XN-3100, XN-9100)