Webinars and Commercial Conversations — Register Now
Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.
Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC
CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.
Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs
CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.
Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida
CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers
Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute
CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Beckman Coulter
DxH 520 Hematology Analyzer
| Company | Beckman Coulter |
|---|---|
| Name of analyzer | DxH 520 Hematology Analyzer |
| Contact | Eric Pabon |
| City, State | Brea, CA |
| Phone | 714-993-5321 |
| Website | |
| Analyzer application | diagnostic and research use |
| Dimensions of analyzer (H × W × D)/Analyzer footprint | 16 × 10.6 × 16.9 in./5.02 sq. ft. |
| Country where analyzer was designed/Manufactured | U.S./U.S. |
| First year analyzer was sold in U.S./Approximate No. of units installed in U.S. (based on August 2026 survey deadline) | 2019/1,250 |
| First year analyzer sold outside U.S./Approximate No. of units installed outside U.S. (based on August 2026 survey deadline) | 2019/>2,015 |
| Foreign locations where company markets analyzer | worldwide (installed worldwide) |
| Human languages (other than English) supported by analyzer | Japanese, Chinese, French, Italian, German, Spanish, Portuguese, Danish, Swedish, Greek, Czech, others |
| Analyzer list price | $40, 000 |
| • Analyzer acquisition options | purchase, lease |
| Training included with purchase/Total time for basic training per operator | yes/8 hours (at customer site and vendor office) |
| • Follow-up training available | yes (extra charge) |
| Parameters that analyzer tests and reports | %&# eosinophils, %&# lymphocytes, %&# monocytes, %&# neutrophils, %&# basophils, Hb, Hct, MCH, MCHC, MCV, PLT, RBC, WBC |
| Types of testing FDA cleared or approved for analyzer | blood count analysis |
| Types of body fluids FDA cleared or approved for analysis on analyzer | — |
| Analytical measurement range for body fluid | — |
| Precision for body fluid | — |
| Accuracy for body fluid | — |
| Automated differential performed for body fluids | no |
| Tests available for research use only | low hemoglobin density, microcytic anemia factor, more |
| Differential methods used | CBC analysis based on Coulter Principle; uses simultaneous measurements of volume, axial light loss within WBC aperture to count and size lymphocytes, monocytes, neutrophils, eosinophils, basophils |
| Analytical measurement range: • WBC count/RBC count | WBC: 0.20–100.00 × 103 cells/μL/RBC: 0.20–8.00 × 106 cells/μL |
| Precision: • WBC count/RBC count | WBC: 0.20 to <1.00 × 103 cells/μL: ≤0.15 SD; 1.00 to 5.00–7.00 × 103 cells/μL: ≤4.00% CV; >7.00–100.00 × 103 cells/μL: ≤3.00% CV/RBC: 1.00–3.50 × 106 cells/μL: ≤3.00% CV; 3.50–8.00 × 106 cells/μL: ≤2.00% CV |
| Accuracy: • WBC count/RBC count | WBC: 0.20–100.00 × 103 cells/μL/RBC: 0.20–8.00 × 106 cells/μL |
| Interfering substances: • WBC/RBC | unlysed RBCs, NRBCs, cryoglobulin, cryofibrinogen, platelet clumps, giant platelets, agglutinated WBCs/agglutinated RBCs, unlysed RBCs, elevated WBCs, more |
| • Hemoglobin/Platelets | lipids >62.5 mg/dL (lipemia)/giant platelets, platelet clumps, microcytic RBCs, cryoglobulin, WBC or RBC fragments |
| • Hematocrit/Reticulocytes | agglutinated RBCs, unlysed RBCs, elevated WBCs, more/— |
| • Automated differential | unlysed RBCs, NRBCs, cryoglobulin, cryofibrinogen, platelet clumps, giant platelets, agglutinated WBCs |
| Throughput: max. CBCs per hour/Max. CBCs with differentials per hour | 60 open vial, 55 closed vial/60 open vial, 55 closed vial |
| • Max. No. of slides processed per hour if stainer included | — |
| FDA-cleared or -approved sample container types (besides potassium EDTA) | none |
| Min. specimen volume open mode/Closed mode/Microsample capability | 16.7 μL/16.7 μL/yes |
| Types of patient data archived/Max. No. of archived patient data accessible when analyzer online | results, flags, demographics/30,000 |
| Analyzer performs delta checks | yes |
| Parameters for which flags may appear | flagging limits, system messages, editing of parameters |
| • Flagging client selectable | yes |
| Analyzer recognizes and holds test results | yes, for follow-up, confirmatory testing, and potential test rerun (parameters for flags to hold samples defined by client or vendor) |
| Scattergram display uses cell-specific color | yes |
| Histogram display uses color with thresholds | yes |
| LIS interface formats supported | proprietary (analyzer or vendor specific), ASTM 1394-91, ASTM 1238-95, IEEE MIB |
| • Middleware interface | no (connects directly to LIS) |
| Analyzer transmits LOINC codes for results to LIS or middleware | yes (also provides list of machine codes for each test and corresponding LOINC code) |
| Lab automation system or workcells to which analyzer has a direct interface | none |
| Barcode symbologies read on specimen tube | Codabar, Code 39, Code 128, Interleaved 2 of 5 |
| • Analyzer allows barcode placement per CLSI standard Auto02-A2 | no |
| No. of onboard reagents required for standard specimen analysis | 3 |
| • Reagents ready to use/Reagent tracking method | yes/barcode reader |
| Time required for analyzer maintenance | 30 min. daily |
| Onboard diagnostics for troubleshooting | no |
| • Manufacturer can perform diagnostics via remote access | no |
| Warranty provided/Cost of annual service contract (24 h/7 d) | one-year warranty/variable |
| Distinguishing analyzer features (supplied by company) | small aspiration: 16.7 μL for open tube, 5-part differential, ideal for infants and difficult draws; small footprint: requires only 3 reagents for full CBC/diff |
| Note | †also marketed by Medline, McKesson, Henry Schein, Thermo Fisher Scientific |