Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Sysmex Corp.

XW-100

Company

Sysmex Corp.

Name of analyzer

XW-100

Contact

Jill Crist  

Email

communications@sysmex.com

City, State

Lincolnshire, IL

Phone

888-879-7639  

Website

http://www.sysmex.com

Analyzer application

diagnostic use

Dimensions of analyzer (H × W × D)/Analyzer footprint 

13.8 × 7.3 × 18.1 in./—

Country where analyzer was designed/Manufactured 

Japan/Japan

First year analyzer was sold in U.S./Approximate No. of units installed in U.S. (based on August 2026 survey deadline) 

2018/>500

First year analyzer sold outside U.S./Approximate No. of units installed outside U.S. (based on August 2026 survey deadline) 

—

Foreign locations where company markets analyzer

—

Human languages (other than English) supported by analyzer 

—

Analyzer list price

$7, 150

• Analyzer acquisition options

purchase

Training included with purchase/Total time for basic training per operator

yes/—

• Follow-up training available

yes (no extra charge)

Parameters that analyzer tests and reports

%&# lymphocytes, %&# neutrophils, Hb, Hct, MCV, PLT, RBC, WBC

Types of testing FDA cleared or approved for analyzer

—

Types of body fluids FDA cleared or approved for analysis on analyzer

—

Analytical measurement range for body fluid

—

Precision for body fluid

—

Accuracy for body fluid

—

Automated differential performed for body fluids

—

Tests available for research use only

—

Differential methods used

direct current with hydrodynamic focusing for all parameters except hemoglobin, which is measured photometrically

Analytical measurement range: • WBC count/RBC count

WBC: 1–63.2 × 103/μL/RBC: 0.3–7.0 × 106/μL

Precision: • WBC count/RBC count

WBC: <3.5%/RBC: <2.0%

Accuracy: • WBC count/RBC count

—

Interfering substances: • WBC/RBC

—

• Hemoglobin/Platelets

—

• Hematocrit/Reticulocytes

—

• Automated differential

—

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

—

• Max. No. of slides processed per hour if stainer included

—

FDA-cleared or -approved sample container types (besides potassium EDTA)

—

Min. specimen volume open mode/Closed mode/Microsample capability

—/15 µL/no

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

none/—

Analyzer performs delta checks

no

Parameters for which flags may appear

—

• Flagging client selectable

no

Analyzer recognizes and holds test results

no 

Scattergram display uses cell-specific color

no

Histogram display uses color with thresholds

no

LIS interface formats supported

—

• Middleware interface

—

Analyzer transmits LOINC codes for results to LIS or middleware

no

Lab automation system or workcells to which analyzer has a direct interface

—

Barcode symbologies read on specimen tube

proprietary barcodes

• Analyzer allows barcode placement per CLSI standard Auto02-A2

no

No. of onboard reagents required for standard specimen analysis

2

• Reagents ready to use/Reagent tracking method

—

Time required for analyzer maintenance

15 min. daily

Onboard diagnostics for troubleshooting

no

• Manufacturer can perform diagnostics via remote access

no

Warranty provided/Cost of annual service contract (24 h/7 d)

—

Distinguishing analyzer features (supplied by company)

CLIA-waived CBC; simple operation 

Note

†also marketed by McKesson

More products
in this guide

Alinity h-series
CELL-DYN Emerald
CELL-DYN Emerald 22
CELL-DYN Emerald 22 Autoloader
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 690T Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
GloCyte Automated Cell Counter for CSF
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series (XN-1000, XN-2000, XN-3100, XN-9100)