Webinars and Sponsored Roundtables — Register Now

Tuesday, October 20, 2026, 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 29, 2026, 1 PM-2 PM ET
Hear an expert discuss the evolving role of PD-L1 testing in HNSCC and ovarian cancer.

Webinar presenter Georgios Deftereos, MD, Professor of Pathology, Associate Director of the Clinical Cancer Genomics Laboratory, Director of Molecular Cytopathology, University of California, San Francisco

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Agilent.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026, 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 10, 2026, 1 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Jeffrey Gregg, MD, University of Nevada

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

CellaVision

DM-9600

Company

CellaVision

Name of analyzer

DM-9600

Contact

Scott Dunbar  

Email

scott.dunbar@cellavision.com

City, State

Durham, NC

Phone

415-810-5994  

Website

http://www.cellavision.com

Analyzer application

diagnostic use

Dimensions of analyzer (H × W × D)/Analyzer footprint 

31.1 × 22.8 × 22 in./3.48 sq. ft. 

Country where analyzer was designed/Manufactured 

Sweden/Sweden

First year analyzer was sold in U.S./Approximate No. of units installed in U.S. (based on August 2026 survey deadline) 

2015/>250

First year analyzer sold outside U.S./Approximate No. of units installed outside U.S. (based on August 2026 survey deadline) 

2014/>800

Foreign locations where company markets analyzer

worldwide (installed worldwide)

Human languages (other than English) supported by analyzer 

German, Spanish, French, Italian, Portuguese, Japanese, simplified Chinese, traditional Chinese, Korean, Russian

Analyzer list price

— (slide maker stainer sold separately)

• Analyzer acquisition options

purchase

Training included with purchase/Total time for basic training per operator

yes/8 hours (at customer site and online)

• Follow-up training available

yes (no extra charge)

Parameters that analyzer tests and reports

%&# eosinophils, %&# immature granulocytes, %&# lymphocytes, %&# monocytes, %&# neutrophils, %&# basophils, PLT, NRBC

Types of testing FDA cleared or approved for analyzer

—

Types of body fluids FDA cleared or approved for analysis on analyzer

CSF, peritoneal/ascites, pericardial fluid, pleural fluid, synovial fluid (differential only)

Analytical measurement range for body fluid

—

Precision for body fluid

—

Accuracy for body fluid

—

Automated differential performed for body fluids

yes (5-part differential)

Tests available for research use only

none

Differential methods used

automated digital image analysis supported by artificial intelligence

Analytical measurement range: • WBC count/RBC count

—

Precision: • WBC count/RBC count

—

Accuracy: • WBC count/RBC count

—

Interfering substances: • WBC/RBC

—

• Hemoglobin/Platelets

—

• Hematocrit/Reticulocytes

—

• Automated differential

—

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

—

• Max. No. of slides processed per hour if stainer included

—

FDA-cleared or -approved sample container types (besides potassium EDTA)

—

Min. specimen volume open mode/Closed mode/Microsample capability

—

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

patient ID, cell images, cell differential/—

Analyzer performs delta checks

—

Parameters for which flags may appear

—

• Flagging client selectable

—

Analyzer recognizes and holds test results

—

Scattergram display uses cell-specific color

—

Histogram display uses color with thresholds

—

LIS interface formats supported

ASTM 1394-91

• Middleware interface

yes (can use Sysmex Caresphere Workflow Solution)

Analyzer transmits LOINC codes for results to LIS or middleware

no

Lab automation system or workcells to which analyzer has a direct interface

—

Barcode symbologies read on specimen tube

Codabar, Data Matrix, Code 39, Code 128

• Analyzer allows barcode placement per CLSI standard Auto02-A2

— (supports QR codes)

No. of onboard reagents required for standard specimen analysis

—

• Reagents ready to use/Reagent tracking method

—

Time required for analyzer maintenance

—

Onboard diagnostics for troubleshooting

yes

• Manufacturer can perform diagnostics via remote access

yes

Warranty provided/Cost of annual service contract (24 h/7 d)

one-year warranty/—

Distinguishing analyzer features (supplied by company)

not a traditional cell counter but a digital cell morphology analyzer; presents high-quality images of preclassified cells

Note

†also marketed by Sysmex

More products
in this guide

Alinity h-series
CELL-DYN Emerald
CELL-DYN Emerald 22
CELL-DYN Emerald 22 Autoloader
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 690T Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
GloCyte Automated Cell Counter for CSF
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series (XN-1000, XN-2000, XN-3100, XN-9100)