Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Beckman Coulter

DxH 690T Hematology Analyzer

Company

Beckman Coulter

Name of analyzer

DxH 690T Hematology Analyzer

Contact

Eric Pabon  

Email

epabon@beckman.com

City, State

Brea, CA

Phone

714-993-5321  

Website

http://www.beckmancoulter.com

Analyzer application

diagnostic and research use

Dimensions of analyzer (H × W × D)/Analyzer footprint 

40.6 × 29.75 × 32.6 in./9.09 sq. ft.

Country where analyzer was designed/Manufactured 

U.S./U.S.

First year analyzer was sold in U.S./Approximate No. of units installed in U.S. (based on August 2026 survey deadline) 

2020/>530

First year analyzer sold outside U.S./Approximate No. of units installed outside U.S. (based on August 2026 survey deadline) 

2020/>410

Foreign locations where company markets analyzer

worldwide (installed worldwide)

Human languages (other than English) supported by analyzer 

Japanese, Chinese, French, Italian, German, Spanish, Portuguese, Swedish, Greek, Czech, Hungarian, others

Analyzer list price

$218,000 (slide maker stainer sold separately)

• Analyzer acquisition options

purchase, lease

Training included with purchase/Total time for basic training per operator

yes/20 hours (at customer site and vendor office)

• Follow-up training available

yes (extra charge)

Parameters that analyzer tests and reports

%&# eosinophils, %&# lymphocytes, %&# monocytes, %&# neutrophils, %&# basophils, %&# reticulocyte count, Hb, Hct, MCH, MCHC, MCV, PLT, RBC, NRBC, WBC

Types of testing FDA cleared or approved for analyzer

blood count analysis, body fluid analysis

Types of body fluids FDA cleared or approved for analysis on analyzer

CSF, synovial fluid, serous fluid

Analytical measurement range for body fluid

RBC count: 1,000–6,200,000 cells/mm3; TNC count: 20–89,000 cells/mm3

Precision for body fluid

RBC count: 10,000–15,000 cells/mm3; TNC count: 50–2,000 cells/mm3

Accuracy for body fluid

RBC count: 1,000–6,200,000 cells/mm3; TNC count: 20–89,000 cells/mm3

Automated differential performed for body fluids

no

Tests available for research use only

body fluid mononuclear cell %, more

Differential methods used

prepared sample transferred to multi-transducer module, with cells counted in an isometric sample stream; algorithm analysis separates WBC into 5 populations

Analytical measurement range: • WBC count/RBC count

WBC: 0.050–400.000 × 103 cells/μL/RBC: 0.005–8.500 × 106 cells/μL

Precision: • WBC count/RBC count

WBC: 05.00–2.000 × 103 cells/μL: ≤5.0% CV; 5.000–10.000 × 103 cells/μL: ≤3.0% CV/RBC: 4.500–5.500 × 106 cells/μL

Accuracy: • WBC count/RBC count

WBC: 0.050–2.000 × 103 cells/μL ±0.1 or ±10%; >2.000–100.000 × 103 cells/μL ±0.2 or ±3.0%; >100.00–400.00 × 103 cells/μL ±5.0%/RBC: 0.005–8.500 × 106 cells/μL

Interfering substances: • WBC/RBC

NRBCs, giant platelets, platelet clumps, malarial parasites, precipitated elevated proteins, more/very high WBC count, high concentration of very large platelets, autoagglutination

• Hemoglobin/Platelets

severe lipemia, heparin, certain unusual RBC abnormalities that resist lysing/giant platelets, platelet clumps, WBC and RBC fragments, electronic noise, very small RBCs

• Hematocrit/Reticulocytes

very high WBC count, high concentration of very large platelets, more/erythrocyte inclusions stained by new methylene blue if sufficiently numerous within sample, more

• Automated differential

hypogranular granulocytes, agranular granulocytes, lyse-resistant RBCs, elevated triglycerides, more

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

100/100

• Max. No. of slides processed per hour if stainer included

—

FDA-cleared or -approved sample container types (besides potassium EDTA)

none

Min. specimen volume open mode/Closed mode/Microsample capability

165 μL/165 μL/yes

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

results, including graphics, raw data files/100,000

Analyzer performs delta checks

yes

Parameters for which flags may appear

delta checks, reference range flags, action limit flags, critical limit flags, suspect messages, more

• Flagging client selectable

yes

Analyzer recognizes and holds test results

yes, for follow-up, confirmatory testing, and potential test rerun (parameters for flags to hold samples defined by client or vendor)

Scattergram display uses cell-specific color

yes

Histogram display uses color with thresholds

yes

LIS interface formats supported

proprietary (analyzer or vendor specific), ASTM 1394-91, ASTM 1238-95, IEEE MIB

• Middleware interface

yes (can use company’s middleware)

Analyzer transmits LOINC codes for results to LIS or middleware

yes (also provides list of machine codes for each test and corresponding LOINC code)

Lab automation system or workcells to which analyzer has a direct interface

Beckman Coulter

Barcode symbologies read on specimen tube

Codabar, Code 39, Code 128, Interleaved 2 of 5, NW-7, ASTM

• Analyzer allows barcode placement per CLSI standard Auto02-A2

yes

No. of onboard reagents required for standard specimen analysis

4

• Reagents ready to use/Reagent tracking method

yes/barcode reader

Time required for analyzer maintenance

30 min. daily

Onboard diagnostics for troubleshooting

yes

• Manufacturer can perform diagnostics via remote access

yes

Warranty provided/Cost of annual service contract (24 h/7 d)

one-year warranty/variable

Distinguishing analyzer features (supplied by company)

benchtop system minimizes slide reviews, maximizes lab staff time, provides cost savings for mid-volume labs

More products
in this guide

Alinity h-series
CELL-DYN Emerald
CELL-DYN Emerald 22
CELL-DYN Emerald 22 Autoloader
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
GloCyte Automated Cell Counter for CSF
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series (XN-1000, XN-2000, XN-3100, XN-9100)