Webinars and Sponsored Roundtables — Register Now

Wednesday, September 30, 2026. 1 PM-1:30 PM ET
Roundtable presenters John Longshore, PhD, Head of Scientific Affairs, Global Oncology Diagnostics, AstraZeneca, and Flora Berisha, MS, Executive Director, Global Head of Diagnostic Partnering and Development, Johnson & Johnson Innovative Medicine, and Mark D. Ewalt, MD, Associate Medical Director for Laboratory Operations, Diagnostic Molecular Pathology, Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, and Isabel Preeshagul, DO, MBS, Thoracic Medical Oncologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The roundtable is made possible by a special educational grant from Pillar Biosciences.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 1, 2026 1 PM-2 PM ET
This presentation will explore the value of in-house CGP, offer insights into the benefits and drawbacks of incorporation, and provide information about important practical factors when considering in-house implementation of CGP.

Webinar presenter Allison M. Cushman-Vokoun, MD, PhD, FCAP, Medical Director, Molecular Diagnostics and Personalized Medicine Laboratory, Director, Division of Diagnostic Molecular Pathology and Human Genetics, Henry F. Krous Professor of Pathology, University of Nebraska Medical Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Illumina.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, October 20, 2026 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Abbott

CELL-DYN Emerald†

Company

Abbott

Name of analyzer

CELL-DYN Emerald†

Contact

James Pickering

Email

james.pickering@abbott.com

City, State

Lake Forest, IL

Phone

800-323-9100

Website

https://www.corelaboratory.abbott

Analyzer application

diagnostic use

Dimensions of analyzer (H × W ×

13.8 × 9.8 × 13.8 in./—

Country where analyzer was

U.S./Germany

First year analyzer was sold in U.S./Approximate No. of units installed in U.S.*

2009/766

First year analyzer sold outside

2008/1, 513

Foreign locations where company

Brazil, Canada, Italy, Japan, Saudi Arabia, Spain, U.K., Vietnam, more (installed in the aforementioned countries)

Human languages (other than

French, Italian, German, Spanish, Bulgarian, more

Analyzer list price

— 

• Analyzer acquisition options

purchase, trade in, lease, reagent rental agreement

Training included with purchase/Total time for basic training per operator

15 min. weekly; ~10 min. biannualy

• Follow-up training available

yes (extra charge)

Parameters that analyzer tests and reports

%&# lymphocytes, %&# neutrophils, Hb, Hct, MCH, MCHC, MCV, PLT, RBC, WBC, more

Types of testing FDA cleared or approved for analyzer

—

Types of body fluids FDA cleared or approved for analysis on analyzer

—

Analytical measurement range for body fluid

—

Precision for body fluid

—

Accuracy for body fluid

—

Automated differential performed for body fluids

—

Tests available for research use only

—

Differential methods used

electrical impedance counting

Analytical measurement range: • WBC count/RBC count

WBC: 0.4–96.1 K/µL/RBC: 0.22–7.61 M/µL

Precision: • WBC count/RBC count

WBC: 3.5% CV/RBC: 2.0% CV

Accuracy: • WBC count/RBC count

—

Interfering substances: • WBC/RBC

cryoglobulin, cryofibrinogen, heparin, monoclonal proteins, NRBCs, platelet clumping, unlysed RBCs, clotting, smudge cells, more/cryoglobulin, cryofibrinogen, giant platelets, high WBC count (>50, 000 K/µL), autoagglutination, more

• Hemoglobin/Platelets

carboxyhemoglobin (>10%), cryoglobulin, cryofibrinogen, in vivo hemolysis, heparin, high WBC count (>50, 000 K/µL), more/cryoglobulin, cryofibrinogen, in vivo and in vitro hemolysis, microcytic RBCs, RBC inclusions, more

• Hematocrit/Reticulocytes

cryoglobulin, cryofibrinogen, giant platelets, high WBC count (>50, 000 K/μL), hyperglycemia (>600 mg/dL), autoagglutination, clotting, in vitro hemolysis, more/—

• Automated differential

platelet aggregates, NRBCs, giant platelets, cryoglobulin, incomplete lysis of RBCs, small lymphocytes, fibrin clots, more

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

57/57

• Max. No. of slides processed per hour if stainer included

—

FDA-cleared or -approved sample container types (besides potassium EDTA)

none

Min. specimen volume open mode/Closed mode/Microsample capability

9.8 µL/—/no

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

patient demographics, previous test results, more (customizable)/300, 000 on USB, 1, 500 results on internal memory

Analyzer performs delta checks

no

Parameters for which flags may appear

dispersed data alerts, suspect measurand flags, count invalidation flags

Analyzer recognizes and holds test results

no

Scattergram display uses cell-specific color

no

Histogram display uses color with thresholds

no

LIS interface formats supported

proprietary (analyzer or vendor specific)

• Middleware interface

yes (can use company’s middleware or third-party middleware or connect directly to LIS)

• Information transferred to LIS via middleware or LIS interface

numeric results, flagged results

Analyzer transmits LOINC codes for results to LIS or middleware

no

Lab automation system or workcells to which analyzer has a direct interface

none

Barcode symbologies read on specimen tube

Codabar, Code 39, Code 128, Interleaved 2 of 5, Code 93, EAN8, EAN13, EAN128, IATA, Matrix 2 of 5, more

• Analyzer allows barcode placement per CLSI standard Auto02-A2

no

No. of onboard reagents required for standard specimen analysis

2

• Reagents ready to use/Reagent tracking method

yes/barcode reader

Onboard diagnostics for troubleshooting

no

• Manufacturer can perform diagnostics via remote access

no

Warranty provided/Cost of annual service contract (24 h/7 d)

one-year warranty/variable

Notes

†also marketed by distributors

More products
in this guide

Alinity h-series
CELL-DYN Emerald 22
CELL-DYN Emerald 22 Autoloader
GloCyte Automated Cell Counter for CSF
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 690T Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series† (XN-1000, XN-2000, XN-3100, XN-9100)