Webinars and Sponsored Roundtables — Register Now

Tuesday, October 20, 2026, 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 29, 2026, 1 PM-2 PM ET
Hear an expert discuss the evolving role of PD-L1 testing in HNSCC and ovarian cancer.

Webinar presenter Georgios Deftereos, MD, Professor of Pathology, Associate Director of the Clinical Cancer Genomics Laboratory, Director of Molecular Cytopathology, University of California, San Francisco

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Agilent.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026, 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 10, 2026, 1 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Jeffrey Gregg, MD, University of Nevada

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Abbott

CELL-DYN Emerald 22 Autoloader

Company

Abbott

Name of analyzer

CELL-DYN Emerald 22 Autoloader

Contact

Maria Chavez  

Email

maria.chavez@abbott.com

City, State

Lake Forest, IL

Phone

800-323-9100  

Website

http://www.corelaboratory.abbott

Analyzer application

diagnostic use

Dimensions of analyzer (H × W × D)/Analyzer footprint 

16.1 × 19.7 × 17 in./—

Country where analyzer was designed/Manufactured 

U.S./Germany

First year analyzer was sold in U.S./Approximate No. of units installed in U.S. (based on August 2026 survey deadline) 

2019/32

First year analyzer sold outside U.S./Approximate No. of units installed outside U.S. (based on August 2026 survey deadline) 

—/351

Foreign locations where company markets analyzer

Brazil, Canada, Italy, Japan, Saudi Arabia, Spain, U.K., Vietnam, more (installed in the aforementioned countries)

Human languages (other than English) supported by analyzer 

French, Italian, German, Spanish, more

Analyzer list price

$75, 000

• Analyzer acquisition options

purchase, trade in, lease, reagent rental agreement

Training included with purchase/Total time for basic training per operator

yes/— (at customer site)

• Follow-up training available

yes (extra charge)

Parameters that analyzer tests and reports

%&# eosinophils, %&# lymphocytes, %&# monocytes, %&# neutrophils, %&# basophils, Hb, Hct, MCH, MCHC, MCV, PLT, RBC, WBC

Types of testing FDA cleared or approved for analyzer

—

Types of body fluids FDA cleared or approved for analysis on analyzer

—

Analytical measurement range for body fluid

—

Precision for body fluid

—

Accuracy for body fluid

—

Automated differential performed for body fluids

—

Tests available for research use only

—

Differential methods used

Uni-Flow optical technology

Analytical measurement range: • WBC count/RBC count

WBC: 0.4–90 K/µL/RBC: 1.2–8.3 M/µL

Precision: • WBC count/RBC count

WBC: 3.2% CV/RBC: 2.0% CV

Accuracy: • WBC count/RBC count

—

Interfering substances: • WBC/RBC

cryoglobulin, cryofibrinogen, heparin, monoclonal proteins, NRBCs, platelet clumping, unlysed RBCs, more/cryoglobulin, cryofibrinogen, giant platelets, high WBC count (>50,000 K/µL), autoagglutination, clotting, more

• Hemoglobin/Platelets

carboxyhemoglobin (>10%), cryoglobulin, cryofibrinogen, in vivo hemolysis, heparin, hyperbilirubinemia, more/cryoglobulin, cryofibrinogen, in vivo and in vitro hemolysis, microcytic RBCs, RBC inclusions, clotting, heparin, more

• Hematocrit/Reticulocytes

cryoglobulin, cryofibrinogen, giant platelets, high WBC count (>50,000 K/μL), hyperglycemia (>600 mg/dL), autoagglutination, clotting, in vitro hemolysis, microcytic RBCs/—

• Automated differential

platelet aggregates, erythroblasts, small lymphocytes, immature cells, resistant RBCs, more

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

40/40

• Max. No. of slides processed per hour if stainer included

—

FDA-cleared or -approved sample container types (besides potassium EDTA)

none

Min. specimen volume open mode/Closed mode/Microsample capability

21 μL/21 μL/no

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

patient demographics, previous test results, graphics, more (customizable)/300,000 on USB, 1,000 records with histograms on internal memory

Analyzer performs delta checks

no

Parameters for which flags may appear

dispersed data alerts, suspect parameter flags, count invalidation flags

• Flagging client selectable

no

Analyzer recognizes and holds test results

yes, for follow-up, confirmatory testing, and potential test rerun (parameters for flags to hold samples defined by vendor)

Scattergram display uses cell-specific color

yes

Histogram display uses color with thresholds

yes

LIS interface formats supported

proprietary (analyzer or vendor specific)

• Middleware interface

yes (can use company’s middleware or third-party middleware or connect directly to LIS)

Analyzer transmits LOINC codes for results to LIS or middleware

no

Lab automation system or workcells to which analyzer has a direct interface

none

Barcode symbologies read on specimen tube

Codabar, Code 39, Code 128, Interleaved 2 of 5, Code 39 Full ASCII, Code 93, EAN8, EAN13, EAN128, IATA, more

• Analyzer allows barcode placement per CLSI standard Auto02-A2

no

No. of onboard reagents required for standard specimen analysis

2

• Reagents ready to use/Reagent tracking method

yes/barcode reader

Time required for analyzer maintenance

15 min. weekly; ~10 min. quarterly

Onboard diagnostics for troubleshooting

no

• Manufacturer can perform diagnostics via remote access

no

Warranty provided/Cost of annual service contract (24 h/7 d)

one-year warranty/variable

Distinguishing analyzer features (supplied by company)

small footprint, sample size, and No. of reagents used; open tube safe sampling device; closed tube, continuous autoloading with automated rerun

Note

†also marketed by distributors

More products
in this guide

Alinity h-series
CELL-DYN Emerald
CELL-DYN Emerald 22
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 690T Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
GloCyte Automated Cell Counter for CSF
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series (XN-1000, XN-2000, XN-3100, XN-9100)