Webinars and Sponsored Roundtables — Register Now

Tuesday, October 20, 2026, 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 29, 2026, 1 PM-2 PM ET
Hear an expert discuss the evolving role of PD-L1 testing in HNSCC and ovarian cancer.

Webinar presenter Georgios Deftereos, MD, Professor of Pathology, Associate Director of the Clinical Cancer Genomics Laboratory, Director of Molecular Cytopathology, University of California, San Francisco

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Agilent.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026, 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 10, 2026, 1 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Jeffrey Gregg, MD, University of Nevada

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Siemens Healthineers

Atellica HEMA 580

Company

Siemens Healthineers

Name of analyzer

Atellica HEMA 580

Contact

Sheryl Kirk  

Email

sheryl.kirk@siemens-healthineers.com

City, State

Tarrytown, NY

Phone

914-631-8000  

Website

http://www.siemens-healthineers.com/en-us

Analyzer application

diagnostic and research use

Dimensions of analyzer (H × W × D)/Analyzer footprint 

28.8 × 34.3 × 26.4 in./~6.3 sq. ft.

Country where analyzer was designed/Manufactured 

France/France

First year analyzer was sold in U.S./Approximate No. of units installed in U.S. (based on August 2026 survey deadline) 

2026/—

First year analyzer sold outside U.S./Approximate No. of units installed outside U.S. (based on August 2026 survey deadline) 

2023/700

Foreign locations where company markets analyzer

—

Human languages (other than English) supported by analyzer 

—

Analyzer list price

$265,900 (slide maker stainer sold separately)

• Analyzer acquisition options

purchase, trade in, lease, reagent rental agreement

Training included with purchase/Total time for basic training per operator

yes/≤ 2 days (at customer site)

• Follow-up training available

yes (extra charge)

Parameters that analyzer tests and reports

%&# eosinophils, %&# immature granulocytes, %&# lymphocytes, %&# monocytes, %&# neutrophils, %&# basophils, %&# reticulocyte count, Hb, Hct, MCH, MCHC, MCV, PLT, RBC, NRBC, WBC

Types of testing FDA cleared or approved for analyzer

blood count analysis, body fluid analysis, LPF, PLTo, RHCc, TNC

Types of body fluids FDA cleared or approved for analysis on analyzer

CSF, peritoneal/ascites, pleural fluid, synovial fluid 

Analytical measurement range for body fluid

WBC count: 5–10,000 cells/mm3; RBC count: 1,500–5,000,000 cells/mm3; TNC count: 5–10,000 cells/mm3

Precision for body fluid

WBC count: 15–10,000 cells/mm3; RBC count: 10,000–500,000 cells/mm3; TNC count: 5–10,000 cells/mm3

Accuracy for body fluid

WBC count: ±12%; RBC count: ±12%; TNC count: ±12%

Automated differential performed for body fluids

yes (2-part differential, BFWBC, BFRBC, %&# BFMN, %&# BFPN) 

Tests available for research use only

PDW, PCT, MIC%, MAC%, P-LCC, P-LCR, %&# ALY, %&# LIC, %&# IML, %&# IMM, RETL%, RETM%, RETH%, MRV

Differential methods used

flow cytometry using optical extinction

Analytical measurement range: • WBC count/RBC count

WBC: 0.10–300 × 103/mm3/RBC: 0.2–8 × 106/mm3

Precision: • WBC count/RBC count

WBC: 0.5–300 × 103/mm3/RBC: 0.5–8 × 106/mm3

Accuracy: • WBC count/RBC count

WBC: ±0.3%/RBC: ±0.2%

Interfering substances: • WBC/RBC

unlysed RBCs, hemolysis in vitro, PLT aggregates or macrothrombocytes, cryoglobulin, cryofibrinogen, more/RBC autoagglutination, cold agglutinins, RBC fragments (schizocytes), microcytes, hyperleukocytosis, thrombocytosis, more

• Hemoglobin/Platelets

increase in turbidity (hyperleukocytosis, hyperlipidemia, hyperproteinemia, hyperbilirubinemia), fetal blood, hemolysis/RBC agglutination, RBC inclusions, RBC fragments (schistocytes), microcytes, hemolysis, more

• Hematocrit/Reticulocytes

RBC agglutination, glycemia, hyperleukocytosis, thrombocytosis, macrothrombocytosis, more/Heinz bodies, RBC autofluorescence, parasites (e.g. malaria, babesia), hemolysis, more

• Automated differential

monocytes: presence of large lymphocytes, atypical lymphocytes, blasts, basophils; basophils: presence of hyperleukocytosis, immature cells; more

Throughput: max. CBCs per hour/Max. CBCs with differentials per hour

120/120

• Max. No. of slides processed per hour if stainer included

120

FDA-cleared or -approved sample container types (besides potassium EDTA)

—

Min. specimen volume open mode/Closed mode/Microsample capability

250 µL/250 µL/yes

Types of patient data archived/Max. No. of archived patient data accessible when analyzer online

patient demographics, previous test results, patient sample ID, histograms, graphics, flags, more/up to 100,000 patient records including graphics

Analyzer performs delta checks

no

Parameters for which flags may appear

reference/panic range flags, analytical flags, morphology/suspect information, delta-check flags 

• Flagging client selectable

combination of client and vendor selectable

Analyzer recognizes and holds test results

yes, for follow-up, confirmatory testing, and potential test rerun (parameters for flags to hold samples defined by client or vendor)

Scattergram display uses cell-specific color

yes

Histogram display uses color with thresholds

yes

LIS interface formats supported

proprietary (analyzer or vendor specific), ASTM 1394, HL7 version 2.5 supported via Atellica Data Manager

• Middleware interface

no (connects directly to LIS)

Analyzer transmits LOINC codes for results to LIS or middleware

yes (also provides list of machine codes for each test and corresponding LOINC code)

Lab automation system or workcells to which analyzer has a direct interface

available, installed, operational (to Siemens Healthineers)

Barcode symbologies read on specimen tube

Codabar (NW-7), Code 39, Code 128

• Analyzer allows barcode placement per CLSI standard Auto02-A2

yes

No. of onboard reagents required for standard specimen analysis

5

• Reagents ready to use/Reagent tracking method

yes/barcode reader

Time required for analyzer maintenance

15 min. weekly or after 1,000 analyses

Onboard diagnostics for troubleshooting

yes

• Manufacturer can perform diagnostics via remote access

yes

Warranty provided/Cost of annual service contract (24 h/7 d)

one-year warranty/—

Distinguishing analyzer features (supplied by company)

performs CBC/diff 20 percent faster than standard systems in its class; patented 360 degree mixing provides thorough, consistent sample mixing for reliable results

More products
in this guide

Alinity h-series
CELL-DYN Emerald
CELL-DYN Emerald 22
CELL-DYN Emerald 22 Autoloader
DxH 500 Hematology Analyzer
DxH 520 Hematology Analyzer
DxH 560 AL Hematology Analyzer
DxH 690T Hematology Analyzer
DxH 900 Workcell Automated Hematology Solution
ABX Micros 60
ABX Micros ES60
ABX Pentra 60C+
ABX Pentra XL80
Yumizen H2500
GloCyte Automated Cell Counter for CSF
X100/X100HT with Full-Field Peripheral Blood Smear Application
XN-330, XN-430, XN-530
XN-350, XN-450, XN-550
XN Series (XN-1000, XN-2000, XN-3100, XN-9100)