Webinars and Sponsored Roundtables — Register Now
Wednesday, September 30, 2026. 1 PM-1:30 PM ET
Roundtable presenters John Longshore, PhD, Head of Scientific Affairs, Global Oncology Diagnostics, AstraZeneca, and Flora Berisha, MS, Executive Director, Global Head of Diagnostic Partnering and Development, Johnson & Johnson Innovative Medicine, and Mark D. Ewalt, MD, Associate Medical Director for Laboratory Operations, Diagnostic Molecular Pathology, Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, and Isabel Preeshagul, DO, MBS, Thoracic Medical Oncologist, Memorial Sloan Kettering Cancer Center
CAP TODAY does not endorse any of the products or services named within. The roundtable is made possible by a special educational grant from Pillar Biosciences.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Thursday, October 1, 2026 1 PM-2 PM ET
This presentation will explore the value of in-house CGP, offer insights into the benefits and drawbacks of incorporation, and provide information about important practical factors when considering in-house implementation of CGP.
Webinar presenter Allison M. Cushman-Vokoun, MD, PhD, FCAP, Medical Director, Molecular Diagnostics and Personalized Medicine Laboratory, Director, Division of Diagnostic Molecular Pathology and Human Genetics, Henry F. Krous Professor of Pathology, University of Nebraska Medical Center
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Illumina.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, October 20, 2026 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.
Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, November 3, 2026 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.
Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Binding Site, part of Thermo Fisher Scientific
Optilite
| Company | Binding Site, part of Thermo Fisher Scientific |
|---|---|
| Name of instrument | Optilite |
| Contact | Haley Braffett |
| City, State | San Diego, CA |
| Phone | 858-291-4556 |
| Website | |
| Type of instrument | chemistry |
| List price/First year sold in U.S. | $111,521/2015 |
| Targeted hospital bed size/Targeted test volume | > 100/daily: > 50; monthly: ~1,000; annual: ~12,000 |
| Company manufactures instrument | yes |
| Other models in this family of analyzers | — |
| No. of units in clinical use in U.S./Outside U.S. (countries) | 360/1,611 (Europe, Latin America, Asia-Pacific, Middle East) |
| Dimensions (H × W × D)/Instrument footprint | 24.4 × 37 × 27.6 in./7.09 sq. ft. |
| Weight empty/Weight fully loaded | 242 lbs./~260 lbs. |
| No. of different measured assays onboard simultaneously | 36 (36 can be run and calibrated at one time) |
| No. of user-definable (open chemistry) channels | 10 |
| Test throughput per hour/Assay run time | 120/8–23 min. (avg. 13 min.) |
| No. of direct ion-selective electrode channels | — |
| Detection methods | turbidimetry |
| Stat time until completion/specimen throughput for Ion-selective electrode | — |
| Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel | — |
| Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel | — |
| Typical time delay from ordering stat test until aspiration of sample | — |
| Fully automated microplate immunoassay system | — |
| Methodologies supported | — |
| Separation methodologies | — |
| Stat time until completion of a ß-hCG test | — |
| Stat time until completion of a cTn test | — |
| • Typical time delay from test order to aspiration of sample | — |
| Reagents refrigerated onboard/Reagents ready to use | yes (8°–10°C below ambient)/yes |
| Reagent lot tracking/Reagent inventory | yes/yes |
| Reagent form/Reagents barcoded | liquid chemistry (closed reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/no |
| Walkaway capability/Walkaway duration | yes/90 min. or 54 specimens or 180 tests |
| Design of sample-handling system | rack |
| Uses washable cuvettes/Uses disposable cuvettes | no/yes (can store up to 360 cuvettes) |
| Min.–max. sample volume that can be aspirated at one time | 2–200 µL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 120 µL/assay dependent/150 µL |
| Dedicated pediatric sample cup | yes (dead volume: 150 µL) |
| Primary tube sampling | yes |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | yes/yes (13 × 75 mm, 12 × 75 mm) |
| Pierces caps on primary tubes | no |
| Protects against probe collision | yes |
| Detects clots/liquid level/short sample | yes/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | detection for hemolysis, clots; icterus, lipemia not available |
| Dilutes patient samples onboard/Susceptibility to carryover | yes (can be programmed to perform dilutions prior to analysis)/— |
| Automatic rerun capability | yes |
| Sample volume can be diluted to rerun out-of-linear-range high results | yes |
| Sample volume can be concentrated to rerun out-of-linear-range low results | yes |
| Autocalibration/Multipoint calibration supported | no (calibrants are not stored onboard)/yes (recommended avg. frequency: per lab protocol and every new lot) |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | — |
| Automatic programmable start/Automatic programmable shutdown | no/no |
| Onboard real-time QC/Onboard software capability to review QC | yes/yes |
| Supports multiple QC lot numbers per analyte | no |
| Waste management | automated collection onboard instrument |
| Sample barcode-reading capability/Autodiscrimination | yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/no |
| Lab can control analyzer from remote computer | no |
| Instrument can diagnose its own malfunctions | no (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | no |
| UPS backup power supply | yes |
| Data-management capability/LIS or EHR systems interfaced | onboard/Epic, Clinisys, Oracle Health, SCC Soft Computer |
| LIS interface provided/Bidirectional interface capability | yes (additional cost)/yes (broadcast download and host query) |
| Modem servicing provided/Service engineer on-site response time | no/next business day |
| Mean time between failures | 502 days (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: 10 min.; weekly: 15 min.; monthly: 30 min. |
| Maintenance records kept onboard for user/vendor | some records (log)/no |
| Maintenance training demonstration module onboard | no |
| Training included with purchase/Avg. time for basic user training | yes (2 training slots)/2 days (primarily at customer site) |
| Advanced operator training/Extra charge for follow-up or advanced training | yes (at customer site)/$2,500 |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year)/$12,950 |
| Distinguishing features (supplied by company) | reduced carryover due to disposable cuvettes; dilution cascade to final result; intuitive software that includes three different antigen excess protection methods, optimized by assay |