Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Diasorin

LIAISON XL

Company

Diasorin

Name of instrument

LIAISON XL

Contact

Technical Support   

Email

tech.support@diasorin.com

City, State

Stillwater, MN

Phone

800-328-1482 or 651-439-9710   

Website

http://www.diasorin.com

Type of instrument

immunoassay

List price/First year sold in U.S.

—/2010

Targeted hospital bed size/Targeted test volume

> 300/annual: > 50,000

Company manufactures instrument

no

Other models in this family of analyzers

LIAISON XS

No. of units in clinical use in U.S./Outside U.S. (countries)

> 950/> 6,500 (Continental Europe, Israel, Canada, Mexico, Brazil, China, India, Australia)

Dimensions (H × W × D)/Instrument footprint

59 × 59 × 36 in./14.6 sq. ft.

Weight empty/Weight fully loaded

—/661 lbs.

No. of different measured assays onboard simultaneously

25

No. of user-definable (open chemistry) channels

0

Test throughput per hour/Assay run time

up to 170 (31 tests in throughput)/16–65 min. (avg. 35 min.)

No. of direct ion-selective electrode channels

—

Detection methods

—

Stat time until completion/specimen throughput for Ion-selective electrode

—

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

—

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

—

Typical time delay from ordering stat test until aspiration of sample

—

Fully automated microplate immunoassay system

no

Methodologies supported

chemiluminescence

Separation methodologies

magnetic particle

Stat time until completion of a ß-hCG test

—

Stat time until completion of a cTn test

—

• Typical time delay from test order to aspiration of sample

—

Reagents refrigerated onboard/Reagents ready to use

yes (13°±2°C)/yes

Reagent lot tracking/Reagent inventory

yes/no

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/360 min. 

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

no/yes (can store up to 800 cuvettes)

Min.–max. sample volume that can be aspirated at one time 

50–1,000 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

—/15 µL/150 µL

Dedicated pediatric sample cup

yes (dead volume: 50 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for hemolysis, icterus, lipemia, clots

Dilutes patient samples onboard/Susceptibility to carryover

no/—

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Autocalibration/Multipoint calibration supported

yes (calibrants can be stored onboard)/yes (recommended avg. frequency: assay dependent)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/—/—/—/assay dependent

Automatic programmable start/Automatic programmable shutdown

yes (15 min. warm-up time)/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

automated collection onboard instrument or direct to drain

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/Meditech, Oracle Health, Veradigm, Epic, CompuGroup Medical, Comtron, Aspyra, NetLims, LabHealth, McKesson, Starlims, more

LIS interface provided/Bidirectional interface capability

no/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

no/48 hrs.

Mean time between failures

2.9–4.1 months (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 0 min.; weekly: 10 min.; monthly: 30 min.

Maintenance records kept onboard for user/vendor

yes/some records (post-service/maintenance requalification data)

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes (3 training slots)/2–3 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at vendor site)/no

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

secure traceability of all processes, status of reagents, and consumables; disposable pipette tips prevent sample carryover; no daily maintenance–instrument monitors maintenance needs

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Pictus 700 (P700)
Agility Automated ELISA System
AIX1000 Agglutination Instrument
Yumizen C1200
Yumizen C560
VITROS 3600 Immunodiagnostic System
VITROS 4600 Chemistry System
cobas pro integrated solutions
dIFine P30 Processor
IMMULITE 2000 XPi Immunoassay System
Phadia 250 Laboratory System
B⋅R⋅A⋅H⋅M⋅S KRYPTOR GOLD
QUANTA-Lyser 3000