Webinars and Sponsored Roundtables — Register Now

Tuesday, July 21, 2026, 11:00-11:30 AM CT

Learning Objectives:
  • Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
  • Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
  • Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.

Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.

Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Roche Diagnostics

cobas pro integrated solutions

Company

Roche Diagnostics

Name of instrument

cobas pro integrated solutions

Contact

Brianna Frederick    

Email

brianna.frederick@roche.com

City, State

Indianapolis, IN

Phone

800-428-5074   

Website

go.roche.com/cobasproUSA

Type of instrument

combination chemistry/immunoassay

List price/First year sold in U.S.

—/2019

Targeted hospital bed size/Targeted test volume

150/daily: > 150; monthly: > 2,000; annual: > 750,000–4.5 million

Company manufactures instrument

no (manufactured by Hitachi High-Technologies)

Other models in this family of analyzers

cobas pure integrated solutions

No. of units in clinical use in U.S./Outside U.S. (countries)

> 1,000/> 5,000 (> 40 countries)

Dimensions (H × W × D)/Instrument footprint

193.8 × 175.5 × 214.3 in. for integrated 2-module system/54 sq. ft. 

Weight empty/Weight fully loaded

4,564.2 lbs./4,564.2 lbs.

No. of different measured assays onboard simultaneously

chem: 73 (73 can be run and calibrated at one time);  immuno: 48 (48 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

10 (10 can be active simultaneously)

Test throughput per hour/Assay run time

up to 6,400 (varies by module)/chem: 4.5–10 min. (avg. 10 min.); immuno: 9–27 min. (avg. 18 min.)

No. of direct ion-selective electrode channels

3 indirect

Detection methods

photometry, potentiometry

Stat time until completion/specimen throughput for Ion-selective electrode

4.5 min. for ISE, 10 min. with CO2/600 specimens per hr.

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

10 min./200 specimens per hr.

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

10 min./100 specimens per hr.

Typical time delay from ordering stat test until aspiration of sample

< 1 min.

Fully automated microplate immunoassay system

no

Methodologies supported

electrochemiluminescence

Separation methodologies

magnetic particle

Stat time until completion of a ß-hCG test

~10 min.

Stat time until completion of a cTn test

~10 min.

• Typical time delay from test order to aspiration of sample

1 min.

Reagents refrigerated onboard/Reagents ready to use

yes (5°–15°C [chemistry], 6°–10°C [immunoassay])/yes

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/yes

Walkaway capability/Walkaway duration

yes/30–45 min. or 300 samples or ~3,000 tests

Design of sample-handling system

5-position rack

Uses washable cuvettes/Uses disposable cuvettes

yes (can store up to 221 cuvettes for chem, 1,575 for immuno)/yes

Min.–max. sample volume that can be aspirated at one time 

1–60 μL

Min. reaction volume/Min. specimen volume/Min. dead volume

75 μL/1.5 μL (chem), 4 μL (immuno)/50 μL

Dedicated pediatric sample cup

yes (dead volume: 30 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes (11 × 102 mm [chem], 13 × 102 mm [immuno])

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

quantitation for hemolysis, icterus, lipemia; detection for clots

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/<1 part per million (chemistry), no carryover (immunoassay)

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Autocalibration/Multipoint calibration supported

yes (calibrants are not stored onboard)/yes (recommended avg. frequency: once per lot [chem], up to 84 days per lot [immuno])

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

once per lot/once per lot/once per lot/once per lot/up to 84 days per lot

Automatic programmable start/Automatic programmable shutdown

yes (6.5 min. start-up time)/yes

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

direct to drain

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

yes

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard, optional add-on (Bio-Rad MAS)/SCC, Oracle Health, Epic, more

LIS interface provided/Bidirectional interface capability

yes (incl. in price)/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

yes/—

Mean time between failures

c 503 module: 220 days; e 801 module: avg. 220 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: ~5 min.; weekly: 0 min.; monthly: ~59 min.

Maintenance records kept onboard for user/vendor

yes/yes (both include audit trail of who replaced parts)

Maintenance training demonstration module onboard

yes

Training included with purchase/Avg. time for basic user training

yes (~2 training slots per module)/~5 days (at customer and vendor sites)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at customer and vendor sites)/yes (cost varies by contract)

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/varies by contract

Distinguishing features (supplied by company)

minimal operator intervention with automated maintenance, automated calibration, and continuous loading of reagents; long onboard reagent (up to 6 months) and calibration stabilities; increase revenue through expanded testing services with broad menu on consolidated platform and fast incubation times

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Pictus 700 (P700)
Agility Automated ELISA System
AIX1000 Agglutination Instrument
Yumizen C1200
Yumizen C560
VITROS 3600 Immunodiagnostic System
VITROS 4600 Chemistry System
VITROS XT 7600 Integrated System
dIFine P30 Processor
IMMULITE 2000 XPi Immunoassay System
B⋅R⋅A⋅H⋅M⋅S KRYPTOR GOLD
QUANTA-Lyser 3000