Webinars and Sponsored Roundtables — Register Now
Wednesday, September 30, 2026. 1 PM-1:30 PM ET
Roundtable presenters John Longshore, PhD, Head of Scientific Affairs, Global Oncology Diagnostics, AstraZeneca, and Flora Berisha, MS, Executive Director, Global Head of Diagnostic Partnering and Development, Johnson & Johnson Innovative Medicine, and Mark D. Ewalt, MD, Associate Medical Director for Laboratory Operations, Diagnostic Molecular Pathology, Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, and Isabel Preeshagul, DO, MBS, Thoracic Medical Oncologist, Memorial Sloan Kettering Cancer Center
CAP TODAY does not endorse any of the products or services named within. The roundtable is made possible by a special educational grant from Pillar Biosciences.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Thursday, October 1, 2026 1 PM-2 PM ET
This presentation will explore the value of in-house CGP, offer insights into the benefits and drawbacks of incorporation, and provide information about important practical factors when considering in-house implementation of CGP.
Webinar presenter Allison M. Cushman-Vokoun, MD, PhD, FCAP, Medical Director, Molecular Diagnostics and Personalized Medicine Laboratory, Director, Division of Diagnostic Molecular Pathology and Human Genetics, Henry F. Krous Professor of Pathology, University of Nebraska Medical Center
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Illumina.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, October 20, 2026 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.
Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Tuesday, November 3, 2026 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.
Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology
CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Roche Diagnostics
cobas pro integrated solutions
| Company | Roche Diagnostics |
|---|---|
| Name of instrument | cobas pro integrated solutions |
| Contact | Brianna Frederick |
| City, State | Indianapolis, IN |
| Phone | 800-428-5074 |
| Website | go.roche.com/cobasproUSA |
| Type of instrument | combination chemistry/immunoassay |
| List price/First year sold in U.S. | —/2019 |
| Targeted hospital bed size/Targeted test volume | 150/daily: > 150; monthly: > 2,000; annual: > 750,000–4.5 million |
| Company manufactures instrument | no (manufactured by Hitachi High-Technologies) |
| Other models in this family of analyzers | cobas pure integrated solutions |
| No. of units in clinical use in U.S./Outside U.S. (countries) | > 1,000/> 5,000 (> 40 countries) |
| Dimensions (H × W × D)/Instrument footprint | 193.8 × 175.5 × 214.3 in. for integrated 2-module system/54 sq. ft. |
| Weight empty/Weight fully loaded | 4,564.2 lbs./4,564.2 lbs. |
| No. of different measured assays onboard simultaneously | chem: 73 (73 can be run and calibrated at one time); immuno: 48 (48 can be run and calibrated at one time) |
| No. of user-definable (open chemistry) channels | 10 (10 can be active simultaneously) |
| Test throughput per hour/Assay run time | up to 6,400 (varies by module)/chem: 4.5–10 min. (avg. 10 min.); immuno: 9–27 min. (avg. 18 min.) |
| No. of direct ion-selective electrode channels | 3 indirect |
| Detection methods | photometry, potentiometry |
| Stat time until completion/specimen throughput for Ion-selective electrode | 4.5 min. for ISE, 10 min. with CO2/600 specimens per hr. |
| Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel | 10 min./200 specimens per hr. |
| Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel | 10 min./100 specimens per hr. |
| Typical time delay from ordering stat test until aspiration of sample | < 1 min. |
| Fully automated microplate immunoassay system | no |
| Methodologies supported | electrochemiluminescence |
| Separation methodologies | magnetic particle |
| Stat time until completion of a ß-hCG test | ~10 min. |
| Stat time until completion of a cTn test | ~10 min. |
| • Typical time delay from test order to aspiration of sample | 1 min. |
| Reagents refrigerated onboard/Reagents ready to use | yes (5°–15°C [chemistry], 6°–10°C [immunoassay])/yes |
| Reagent lot tracking/Reagent inventory | yes/yes |
| Reagent form/Reagents barcoded | liquid chemistry (open reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/yes |
| Walkaway capability/Walkaway duration | yes/30–45 min. or 300 samples or ~3,000 tests |
| Design of sample-handling system | 5-position rack |
| Uses washable cuvettes/Uses disposable cuvettes | yes (can store up to 221 cuvettes for chem, 1,575 for immuno)/yes |
| Min.–max. sample volume that can be aspirated at one time | 1–60 μL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 75 μL/1.5 μL (chem), 4 μL (immuno)/50 μL |
| Dedicated pediatric sample cup | yes (dead volume: 30 µL) |
| Primary tube sampling | yes |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | yes/yes (11 × 102 mm [chem], 13 × 102 mm [immuno]) |
| Pierces caps on primary tubes | no |
| Protects against probe collision | yes |
| Detects clots/liquid level/short sample | yes/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | quantitation for hemolysis, icterus, lipemia; detection for clots |
| Dilutes patient samples onboard/Susceptibility to carryover | yes (can be programmed to perform dilutions prior to analysis)/<1 part per million (chemistry), no carryover (immunoassay) |
| Automatic rerun capability | yes |
| Sample volume can be diluted to rerun out-of-linear-range high results | yes |
| Sample volume can be concentrated to rerun out-of-linear-range low results | yes |
| Autocalibration/Multipoint calibration supported | yes (calibrants are not stored onboard)/yes (recommended avg. frequency: once per lot [chem], up to 84 days per lot [immuno]) |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | once per lot/once per lot/once per lot/once per lot/up to 84 days per lot |
| Automatic programmable start/Automatic programmable shutdown | yes (6.5 min. start-up time)/yes |
| Onboard real-time QC/Onboard software capability to review QC | yes/yes |
| Supports multiple QC lot numbers per analyte | yes |
| Waste management | direct to drain |
| Sample barcode-reading capability/Autodiscrimination | yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/yes |
| Lab can control analyzer from remote computer | yes |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | yes |
| UPS backup power supply | yes |
| Data-management capability/LIS or EHR systems interfaced | onboard, optional add-on (Bio-Rad MAS)/SCC, Oracle Health, Epic, more |
| LIS interface provided/Bidirectional interface capability | yes (incl. in price)/yes (broadcast download and host query) |
| Modem servicing provided/Service engineer on-site response time | yes/— |
| Mean time between failures | c 503 module: 220 days; e 801 module: avg. 220 days (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: ~5 min.; weekly: 0 min.; monthly: ~59 min. |
| Maintenance records kept onboard for user/vendor | yes/yes (both include audit trail of who replaced parts) |
| Maintenance training demonstration module onboard | yes |
| Training included with purchase/Avg. time for basic user training | yes (~2 training slots per module)/~5 days (at customer and vendor sites) |
| Advanced operator training/Extra charge for follow-up or advanced training | yes (at customer and vendor sites)/yes (cost varies by contract) |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year)/varies by contract |
| Distinguishing features (supplied by company) | minimal operator intervention with automated maintenance, automated calibration, and continuous loading of reagents; long onboard reagent (up to 6 months) and calibration stabilities; increase revenue through expanded testing services with broad menu on consolidated platform and fast incubation times |