Webinars and Sponsored Roundtables — Register Now

Tuesday, October 20, 2026, 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 29, 2026, 1 PM-2 PM ET
Hear an expert discuss the evolving role of PD-L1 testing in HNSCC and ovarian cancer.

Webinar presenter Georgios Deftereos, MD, Professor of Pathology, Associate Director of the Clinical Cancer Genomics Laboratory, Director of Molecular Cytopathology, University of California, San Francisco

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Agilent.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026, 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 10, 2026, 1 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Jeffrey Gregg, MD, University of Nevada

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Diatron 

Pictus 700 (P700)

Company

Diatron 

Name of instrument

Pictus 700 (P700)

Contact

Frank Matuszak   

Email

frank.matuszak@diatron.com

City, State

Medley, FL

Phone

833-228-7931   

Website

http://www.diatron.com

Type of instrument

chemistry

List price/First year sold in U.S.

$60,190/2013

Targeted hospital bed size/Targeted test volume

50–250/daily: 1,000–4,000; monthly: 30,000–120,000; annual: 365,000–1,460,000

Company manufactures instrument

—

Other models in this family of analyzers

Pictus 500 (P500)

No. of units in clinical use in U.S./Outside U.S. (countries)

< 100/> 750 (Europe, Latin America, Africa, Middle East, Asia)

Dimensions (H × W × D)/Instrument footprint

39.4 × 38.1 × 26.4 in./7.1 sq. ft.

Weight empty/Weight fully loaded

418 lbs./478 lbs.

No. of different measured assays onboard simultaneously

72 (up to 72 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

—

Test throughput per hour/Assay run time

720/30–1,200 sec. (avg. 300 sec.)

No. of direct ion-selective electrode channels

3

Detection methods

photometry, potentiometry

Stat time until completion/specimen throughput for Ion-selective electrode

2 min./60 specimens per hr.

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

7.5 min./60 specimens per hr.

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

9 min./50 specimens per hr.

Typical time delay from ordering stat test until aspiration of sample

24 sec.

Fully automated microplate immunoassay system

—

Methodologies supported

—

Separation methodologies

—

Stat time until completion of a ß-hCG test

—

Stat time until completion of a cTn test

—

• Typical time delay from test order to aspiration of sample

—

Reagents refrigerated onboard/Reagents ready to use

yes (8° ±2°C)/yes

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/no

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/180 min. or 95 specimens or 1,800 tests

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

yes/yes (can store up to 160 cuvettes)

Min.–max. sample volume that can be aspirated at one time 

2–100 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

180 µL/22 µL/100 µL

Dedicated pediatric sample cup

yes (dead volume: 20 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/no

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for clots; hemolysis, icterus, lipemia not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/30 parts per million

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Autocalibration/Multipoint calibration supported

yes (calibrants can be stored onboard)/yes (recommended avg. frequency: 7 days)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

8 hr./—/7 days/14 days/14 days

Automatic programmable start/Automatic programmable shutdown

no/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

manually by user or direct to drain

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128)/no

Lab can control analyzer from remote computer

yes

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/AP Visions, Medicus, CGM Schuylab, Labtrack, CGM LabDaq, Medytox

LIS interface provided/Bidirectional interface capability

yes (additional cost)/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

no/48 hrs.

Mean time between failures

1 year (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 30 min.; weekly: 1 hr.; monthly: 2 hr.

Maintenance records kept onboard for user/vendor

no/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes (2 training slots)/3 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at customer or vendor site)/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/$5,500

Distinguishing features (supplied by company)

uninterrupted workflow; Windows-based, intuitive, user-friendly software; high-quality components for long stability and result reliability

Note

all information listed was provided to CAP TODAY in 2025; company did not provide updated information by 2026 entry deadline

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Agility Automated ELISA System
AIX1000 Agglutination Instrument
Yumizen C560
VITROS 3600 Immunodiagnostic System
VITROS 4600 Chemistry System
VITROS XT 7600 Integrated System
cobas pro integrated solutions
dIFine P30 Processor
IMMULITE 2000 XPi Immunoassay System
Phadia 250 Laboratory System
QUANTA-Lyser 3000