Webinars and Sponsored Roundtables — Register Now
Tuesday, July 21, 2026, 11:00-11:30 AM CT
- Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
- Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
- Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.
Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.
Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Arlington Scientific
ASI Evolution RPR Syphilis Analyzer
| Company | Arlington Scientific |
|---|---|
| Name of instrument | ASI Evolution RPR Syphilis Analyzer |
| Contact | Mike Ladow |
| City, State | Springville, UT |
| Phone | 800-654-0146 |
| Website | |
| Type of instrument | immunoassay |
| List price/First year sold in U.S. | $50,995/2018 |
| Targeted hospital bed size/Targeted test volume | —/daily: 100; monthly: 3,100; annual: 37,200 |
| Company manufactures instrument | yes (also sold by Fisher Scientific, Cardinal, McKesson, VWR, Medline) |
| Other models in this family of analyzers | — |
| No. of units in clinical use in U.S./Outside U.S. (countries) | 141/10 |
| Dimensions (H × W × D)/Instrument footprint | 19 × 36 × 22 in./6 sq. ft. |
| Weight empty/Weight fully loaded | 78 lbs./— |
| No. of different measured assays onboard simultaneously | 1 (1 can be run and calibrated at one time) |
| No. of user-definable (open chemistry) channels | 0 |
| Test throughput per hour/Assay run time | 190/9–11 min. (avg. 10 min.) |
| No. of direct ion-selective electrode channels | — |
| Detection methods | — |
| Stat time until completion/specimen throughput for Ion-selective electrode | — |
| Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel | — |
| Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel | — |
| Typical time delay from ordering stat test until aspiration of sample | — |
| Fully automated microplate immunoassay system | yes (192 tests per unit; 48 wells per microplate) |
| Methodologies supported | agglutination, flocculation |
| Separation methodologies | none necessary |
| Stat time until completion of a ß-hCG test | — |
| Stat time until completion of a cTn test | — |
| • Typical time delay from test order to aspiration of sample | — |
| Reagents refrigerated onboard/Reagents ready to use | no/yes |
| Reagent lot tracking/Reagent inventory | yes/no |
| Reagent form/Reagents barcoded | liquid chemistry (closed reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/no |
| Walkaway capability/Walkaway duration | yes/62 min. or 192 specimens or 192 tests |
| Design of sample-handling system | rack |
| Uses washable cuvettes/Uses disposable cuvettes | no/— |
| Min.–max. sample volume that can be aspirated at one time | 2–500 µL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 110 µL/300 µL/150 µL |
| Dedicated pediatric sample cup | no |
| Primary tube sampling | yes |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | yes/no |
| Pierces caps on primary tubes | no |
| Protects against probe collision | yes |
| Detects clots/liquid level/short sample | yes/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | detection for clots; hemolysis, icterus, lipemia not available |
| Dilutes patient samples onboard/Susceptibility to carryover | yes/no |
| Automatic rerun capability | no |
| Sample volume can be diluted to rerun out-of-linear-range high results | no |
| Sample volume can be concentrated to rerun out-of-linear-range low results | no |
| Autocalibration/Multipoint calibration supported | no (calibrants are not stored onboard)/no |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | — |
| Automatic programmable start/Automatic programmable shutdown | no/no |
| Onboard real-time QC/Onboard software capability to review QC | yes/no |
| Supports multiple QC lot numbers per analyte | no |
| Waste management | manually by user |
| Sample barcode-reading capability/Autodiscrimination | yes (UPC, Code 39, Code 128)/yes |
| Lab can control analyzer from remote computer | no |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | yes |
| UPS backup power supply | no |
| Data-management capability/LIS or EHR systems interfaced | onboard/— |
| LIS interface provided/Bidirectional interface capability | no/no |
| Modem servicing provided/Service engineer on-site response time | no/48 hrs. |
| Mean time between failures | 365 days (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: 10 min.; weekly: 10 min.; monthly: 10 min. |
| Maintenance records kept onboard for user/vendor | no/no |
| Maintenance training demonstration module onboard | no |
| Training included with purchase/Avg. time for basic user training | yes (2 training slots)/0.5 days (at customer site) |
| Advanced operator training/Extra charge for follow-up or advanced training | no/yes |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year limited, service contract required)/varies by tier of service |
| Distinguishing features (supplied by company) | low-cost, automated syphilis test 510(k) cleared for diagnostic, blood donor, and cadaveric screening; can provide dilutions up to 1:2048; 92 percent hands-on time savings compared with manual RPR testing |