Webinars and Sponsored Roundtables — Register Now

Tuesday, July 21, 2026, 11:00-11:30 AM CT

Learning Objectives:
  • Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
  • Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
  • Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.

Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.

Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Siemens Healthineers

IMMULITE 2000 XPi Immunoassay System

Company

Siemens Healthineers

Name of instrument

IMMULITE 2000 XPi Immunoassay System

Contact

Rachel Forsaith   

Email

rachel.forsaith@siemens-healthineers.com

City, State

Tarrytown, NY   

Phone

800-888-7436   

Website

http://www.siemens-healthineers.com/en-us 

Type of instrument

immunoassay

List price/First year sold in U.S.

—/2009

Targeted hospital bed size/Targeted test volume

> 200/daily: > 250

Company manufactures instrument

yes (also sold by McKesson, Henry Schein, Medline, Cardinal)

Other models in this family of analyzers

No. of units in clinical use in U.S./Outside U.S. (countries)

> 300/> 2,400 (75 countries)

Dimensions (H × W × D)/Instrument footprint

72 × 63 × 36 in. (incl. monitor)/15.8 sq. ft.

Weight empty/Weight fully loaded

890 lbs./—

No. of different measured assays onboard simultaneously

24 (1 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

none

Test throughput per hour/Assay run time

up to 200 (up to 24 tests in throughput)/35–125 min. (assay dependent)

No. of direct ion-selective electrode channels

Detection methods

Stat time until completion/specimen throughput for Ion-selective electrode

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

Typical time delay from ordering stat test until aspiration of sample

Fully automated microplate immunoassay system

no

Methodologies supported

chemiluminescence, enzyme immunoassay

Separation methodologies

bead, centrifugation

Stat time until completion of a ß-hCG test

35 min.

Stat time until completion of a cTn test

35 min.

• Typical time delay from test order to aspiration of sample

18 sec.

Reagents refrigerated onboard/Reagents ready to use

yes (2°–8°C)/yes

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/60–300 min.

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

yes/yes (can store up to 1,300 cuvettes)

Min.–max. sample volume that can be aspirated at one time 

5–600 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

—/5 µL/50 µL

Dedicated pediatric sample cup

yes (dead volume: 50 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes (12–16 × 75–100 mm; 10 × 50 mm micro sample tubes)

Pierces caps on primary tubes

no

Protects against probe collision

no

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for clots; hemolysis, icterus, lipemia not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/< 3 parts per million

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Autocalibration/Multipoint calibration supported

yes (calibrants are not stored onboard)/yes (recommended avg. frequency: 1–4 weeks [assay dependent])

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/2 weeks/—/—/1–4 weeks (assay dependent)

Automatic programmable start/Automatic programmable shutdown

— (4 min. warm-up time)/yes

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

manually by user

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

no

Data-management capability/LIS or EHR systems interfaced

onboard/yes

LIS interface provided/Bidirectional interface capability

yes/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

yes/2–8 hrs. 

Mean time between failures

— (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 15 min.; weekly: 20 min.; monthly: 45 min.

Maintenance records kept onboard for user/vendor

no/no

Maintenance training demonstration module onboard

yes

Training included with purchase/Avg. time for basic user training

yes (2 training slots)/2 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at customer site)/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

extensive routine and specialty immunoassay menu; includes menu of more than 300 allergens; specialty testing provides opportunity to reduce send-out test costs and boost revenue; reagent onboard stability of 90 days; automated daily maintenance reduces hands-on time and start-up delays

More products
in this guide

ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Pictus 700 (P700)
Agility Automated ELISA System
AIX1000 Agglutination Instrument
Yumizen C1200
Yumizen C560
VITROS 3600 Immunodiagnostic System
VITROS 4600 Chemistry System
VITROS XT 7600 Integrated System
cobas pro integrated solutions
dIFine P30 Processor
Phadia 250 Laboratory System
B⋅R⋅A⋅H⋅M⋅S KRYPTOR GOLD
QUANTA-Lyser 3000