Webinars and Sponsored Roundtables — Register Now

Tuesday, July 21, 2026, 11:00-11:30 AM CT

Learning Objectives:
  • Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
  • Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
  • Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.

Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.

Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Dynex Technologies

Agility Automated ELISA System

Company

Dynex Technologies

Name of instrument

Agility Automated ELISA System

Contact

Global Customer Service   

Email

customerservice@dynex.com

City, State

Chantilly, VA

Phone

800-288-2354   

Website

http://www.dynex.com

Type of instrument

immunoassay

List price/First year sold in U.S.

—/2012

Targeted hospital bed size/Targeted test volume

Company manufactures instrument

yes

Other models in this family of analyzers

DSX

No. of units in clinical use in U.S./Outside U.S. (countries)

—/425 (worldwide)

Dimensions (H × W × D)/Instrument footprint

47 × 47 × 30.25 in./12.5 sq. ft.

Weight empty/Weight fully loaded

560 lbs./—

No. of different measured assays onboard simultaneously

up to 12 SmartKit reagent packs (up to 12 can be run and calibrated at one time)

No. of user-definable (open chemistry) channels

— (up to 12 can be active simultaneously)

Test throughput per hour/Assay run time

assay dependent (up to 1,536 tests per run)/assay dependent

No. of direct ion-selective electrode channels

Detection methods

Stat time until completion/specimen throughput for Ion-selective electrode

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

Typical time delay from ordering stat test until aspiration of sample

Fully automated microplate immunoassay system

yes (up to 12 tests per unit; 96 wells per microplate)

Methodologies supported

enzyme immunoassay

Separation methodologies

coated microwell

Stat time until completion of a ß-hCG test

Stat time until completion of a cTn test

• Typical time delay from test order to aspiration of sample

Reagents refrigerated onboard/Reagents ready to use

no (23ϒ ±4ϒC)/yes

Reagent lot tracking/Reagent inventory

yes/yes

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/yes

Walkaway capability/Walkaway duration

yes/up to 1,152 specimens or up to 1,152 tests

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

no/no

Min.–max. sample volume that can be aspirated at one time 

10–300 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

10 µL/—/—

Dedicated pediatric sample cup

no

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes (17 × 100 mm)

Pierces caps on primary tubes

no

Protects against probe collision

no

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for clots; hemolysis, icterus, lipemia not available

Dilutes patient samples onboard/Susceptibility to carryover

yes (can be programmed to perform dilutions prior to analysis)/no carryover

Automatic rerun capability

no

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Autocalibration/Multipoint calibration supported

no (calibrants are not stored onboard)/yes (recommended avg. frequency: assay dependent)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/assay dependent/assay dependent/—/assay dependent

Automatic programmable start/Automatic programmable shutdown

no/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

automated collection onboard instrument

Sample barcode-reading capability/Autodiscrimination

yes (UPC, Codabar, Code 39, Code 128, Code 93)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/Clinisys, Oracle Health

LIS interface provided/Bidirectional interface capability

no/yes (host query)

Modem servicing provided/Service engineer on-site response time

no/24 hrs.

Mean time between failures

200 days (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 10 min.; weekly: 5 min.

Maintenance records kept onboard for user/vendor

no/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

no/3 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at customer site)/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

increases productivity–full walkaway processing from beginning of testing with up to 12 SmartKit carriers stored; practical automation–assesses testing requirements, develops efficient work list, continuous sample loading; value–frees up labor time, allows for multitasking by eliminating most of ELISA labor

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Pictus 700 (P700)
AIX1000 Agglutination Instrument
Yumizen C1200
Yumizen C560
VITROS 3600 Immunodiagnostic System
VITROS 4600 Chemistry System
VITROS XT 7600 Integrated System
cobas pro integrated solutions
IMMULITE 2000 XPi Immunoassay System
Phadia 250 Laboratory System
B⋅R⋅A⋅H⋅M⋅S KRYPTOR GOLD
QUANTA-Lyser 3000