Webinars and Sponsored Roundtables — Register Now

Wednesday, September 30, 2026. 1 PM-1:30 PM ET
Roundtable presenters John Longshore, PhD, Head of Scientific Affairs, Global Oncology Diagnostics, AstraZeneca, and Flora Berisha, MS, Executive Director, Global Head of Diagnostic Partnering and Development, Johnson & Johnson Innovative Medicine, and Mark D. Ewalt, MD, Associate Medical Director for Laboratory Operations, Diagnostic Molecular Pathology, Molecular Diagnostics Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, and Isabel Preeshagul, DO, MBS, Thoracic Medical Oncologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The roundtable is made possible by a special educational grant from Pillar Biosciences.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Thursday, October 1, 2026 1 PM-2 PM ET
This presentation will explore the value of in-house CGP, offer insights into the benefits and drawbacks of incorporation, and provide information about important practical factors when considering in-house implementation of CGP.

Webinar presenter Allison M. Cushman-Vokoun, MD, PhD, FCAP, Medical Director, Molecular Diagnostics and Personalized Medicine Laboratory, Director, Division of Diagnostic Molecular Pathology and Human Genetics, Henry F. Krous Professor of Pathology, University of Nebraska Medical Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Illumina.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, October 20, 2026 11 AM-12 PM ET
Hear experts review the biological and clinical significance of the HER2 expression continuum in breast tissue, providing a clearer understanding of how these variations might impact diagnosis, and discuss the emerging importance of documenting HER2-low and HER2-ultralow categories using a validated IHC assay.

Webinar presenters Keith Wharton, MD, PhD, Global Medical Affairs Leader–Pathology, Roche Diagnostics Solutions, and Hannah Y. Wen, MD, PhD, Director, Breast Pathology Fellowship, Associate Team Leader, Breast Pathology Team, Attending Pathologist, Memorial Sloan Kettering Cancer Center

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Roche.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Tuesday, November 3, 2026 1 PM-2 PM ET
Hear an expert discuss the challenges of detecting NRG1 fusions and how RNA-based testing can support more comprehensive fusion identification in clinical practice.

Webinar presenter Benjamin Weinberg, MD, Associate Professor of Medicine and Attending Physician
specializing in gastrointestinal medical oncology

CAP TODAY does not endorse any of the products or services named within. The webinar is made possible by a special educational grant from Diaceutics.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Product Spotlight

Diasorin

LIAISON XL

Company

Diasorin

Name of instrument

LIAISON XL

Contact

Technical Support   

Email

tech.support@diasorin.com

City, State

Stillwater, MN

Phone

800-328-1482 or 651-439-9710   

Website

http://www.diasorin.com

Type of instrument

immunoassay

List price/First year sold in U.S.

—/2010

Targeted hospital bed size/Targeted test volume

> 300/annual: > 50,000

Company manufactures instrument

no

Other models in this family of analyzers

LIAISON XS

No. of units in clinical use in U.S./Outside U.S. (countries)

> 950/> 6,500 (Continental Europe, Israel, Canada, Mexico, Brazil, China, India, Australia)

Dimensions (H × W × D)/Instrument footprint

59 × 59 × 36 in./14.6 sq. ft.

Weight empty/Weight fully loaded

—/661 lbs.

No. of different measured assays onboard simultaneously

25

No. of user-definable (open chemistry) channels

0

Test throughput per hour/Assay run time

up to 170 (31 tests in throughput)/16–65 min. (avg. 35 min.)

No. of direct ion-selective electrode channels

—

Detection methods

—

Stat time until completion/specimen throughput for Ion-selective electrode

—

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

—

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

—

Typical time delay from ordering stat test until aspiration of sample

—

Fully automated microplate immunoassay system

no

Methodologies supported

chemiluminescence

Separation methodologies

magnetic particle

Stat time until completion of a ß-hCG test

—

Stat time until completion of a cTn test

—

• Typical time delay from test order to aspiration of sample

—

Reagents refrigerated onboard/Reagents ready to use

yes (13°±2°C)/yes

Reagent lot tracking/Reagent inventory

yes/no

Reagent form/Reagents barcoded

liquid chemistry (closed reagent system)/yes

Separate reagent pack for each specimen/for each test run

no/no

Walkaway capability/Walkaway duration

yes/360 min. 

Design of sample-handling system

rack

Uses washable cuvettes/Uses disposable cuvettes

no/yes (can store up to 800 cuvettes)

Min.–max. sample volume that can be aspirated at one time 

50–1,000 µL

Min. reaction volume/Min. specimen volume/Min. dead volume

—/15 µL/150 µL

Dedicated pediatric sample cup

yes (dead volume: 50 µL)

Primary tube sampling

yes

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

yes/yes

Pierces caps on primary tubes

no

Protects against probe collision

yes

Detects clots/liquid level/short sample

yes/yes/yes

Detection or quantitation for hemolysis, icterus, lipemia, clots

detection for hemolysis, icterus, lipemia, clots

Dilutes patient samples onboard/Susceptibility to carryover

no/—

Automatic rerun capability

yes

Sample volume can be diluted to rerun out-of-linear-range high results

yes

Sample volume can be concentrated to rerun out-of-linear-range low results

yes

Autocalibration/Multipoint calibration supported

yes (calibrants can be stored onboard)/yes (recommended avg. frequency: assay dependent)

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—/—/—/—/assay dependent

Automatic programmable start/Automatic programmable shutdown

yes (15 min. warm-up time)/no

Onboard real-time QC/Onboard software capability to review QC

yes/yes

Supports multiple QC lot numbers per analyte

yes

Waste management

automated collection onboard instrument or direct to drain

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, UPC, Codabar, Code 39, Code 128)/yes

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

yes (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

yes

UPS backup power supply

yes

Data-management capability/LIS or EHR systems interfaced

onboard/Meditech, Oracle Health, Veradigm, Epic, CompuGroup Medical, Comtron, Aspyra, NetLims, LabHealth, McKesson, Starlims, more

LIS interface provided/Bidirectional interface capability

no/yes (broadcast download and host query)

Modem servicing provided/Service engineer on-site response time

no/48 hrs.

Mean time between failures

2.9–4.1 months (displays error codes for troubleshooting)

Average scheduled maintenance time by lab personnel

daily: 0 min.; weekly: 10 min.; monthly: 30 min.

Maintenance records kept onboard for user/vendor

yes/some records (post-service/maintenance requalification data)

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes (3 training slots)/2–3 days (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

yes (at vendor site)/no

Warranty provided/Cost of annual service contract (24 h/7 d)

yes (1 year)/—

Distinguishing features (supplied by company)

secure traceability of all processes, status of reagents, and consumables; disposable pipette tips prevent sample carryover; no daily maintenance–instrument monitors maintenance needs

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Pictus 700 (P700)
Agility Automated ELISA System
AIX1000 Agglutination Instrument
Yumizen C1200
Yumizen C560
VITROS 3600 Immunodiagnostic System
VITROS 4600 Chemistry System
VITROS XT 7600 Integrated System
IMMULITE 2000 XPi Immunoassay System
Phadia 250 Laboratory System
B⋅R⋅A⋅H⋅M⋅S KRYPTOR GOLD
QUANTA-Lyser 3000