Webinars and Sponsored Roundtables — Register Now
Tuesday, July 21, 2026, 11:00-11:30 AM CT
- Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
- Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
- Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.
Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.
Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
HORIBA
Yumizen C1200
| Company | HORIBA |
|---|---|
| Name of instrument | Yumizen C1200 |
| Contact | Susan Behnke |
| City, State | Irvine, CA |
| Phone | 888-903-5001 |
| Website | |
| Type of instrument | chemistry |
| List price/First year sold in U.S. | $179,800/2020 |
| Targeted hospital bed size/Targeted test volume | < 300/daily: 9,520; monthly: 17,000; annual: 2 million |
| Company manufactures instrument | yes (manufactured by HORIBA ABX SAS; also sold by distribution partners) |
| Other models in this family of analyzers | Yumizen C1200 AL |
| No. of units in clinical use in U.S./Outside U.S. (countries) | — |
| Dimensions (H × W × D)/Instrument footprint | 44 × 48 × 33.5 in./— |
| Weight empty/Weight fully loaded | 992 lbs./— |
| No. of different measured assays onboard simultaneously | 45 (45 can be run and calibrated at one time) |
| No. of user-definable (open chemistry) channels | 100 (100 can be active simultaneously) |
| Test throughput per hour/Assay run time | 1,200 (45 plus 3 ISE tests in throughput)/3–15 min. |
| No. of direct ion-selective electrode channels | 3 |
| Detection methods | photometry, potentiometry, enzyme immunoassay, immunoturbidimetry |
| Stat time until completion/specimen throughput for Ion-selective electrode | 2.4 min./200 specimens per hr. |
| Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel | 12 min./60 specimens per hr. |
| Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel | 12 min./58 specimens per hr. |
| Typical time delay from ordering stat test until aspiration of sample | 81 sec. |
| Fully automated microplate immunoassay system | — |
| Methodologies supported | — |
| Separation methodologies | — |
| Stat time until completion of a ß-hCG test | — |
| Stat time until completion of a cTn test | — |
| • Typical time delay from test order to aspiration of sample | — |
| Reagents refrigerated onboard/Reagents ready to use | yes (2°–8°C)/variable; reagent specific |
| Reagent lot tracking/Reagent inventory | yes/yes |
| Reagent form/Reagents barcoded | liquid chemistry (open reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/no |
| Walkaway capability/Walkaway duration | yes/dependent on reagent |
| Design of sample-handling system | 84 sample continuous loading ring, optional autoloading rack |
| Uses washable cuvettes/Uses disposable cuvettes | yes/no (can store up to 231 cuvettes) |
| Min.–max. sample volume that can be aspirated at one time | 1–25 µL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 80 µL/—/200 µL for primary tube sampling |
| Dedicated pediatric sample cup | yes (dead volume: 50 µL) |
| Primary tube sampling | yes |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | yes/yes |
| Pierces caps on primary tubes | no |
| Protects against probe collision | yes |
| Detects clots/liquid level/short sample | yes/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | detection for hemolysis, icterus, lipemia, clots |
| Dilutes patient samples onboard/Susceptibility to carryover | yes/— |
| Automatic rerun capability | yes |
| Sample volume can be diluted to rerun out-of-linear-range high results | yes |
| Sample volume can be concentrated to rerun out-of-linear-range low results | — |
| Autocalibration/Multipoint calibration supported | yes (calibrants can be stored onboard [ISE])/yes (recommended avg. frequency: with each test kit) |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | daily/for QC failure/for QC failure/per test kit/— |
| Automatic programmable start/Automatic programmable shutdown | yes (40 min. start-up time)/yes |
| Onboard real-time QC/Onboard software capability to review QC | yes/yes |
| Supports multiple QC lot numbers per analyte | no |
| Waste management | direct to drain |
| Sample barcode-reading capability/Autodiscrimination | yes (Interleaved 2 of 5, Codabar, Code 39, Code 128, EAN)/— |
| Lab can control analyzer from remote computer | no |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | yes |
| UPS backup power supply | no |
| Data-management capability/LIS or EHR systems interfaced | onboard/CGM Labdaq |
| LIS interface provided/Bidirectional interface capability | no/yes (broadcast download and host query) |
| Modem servicing provided/Service engineer on-site response time | no/< 24 hrs. |
| Mean time between failures | 122 days (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: 10–15 min. (walkaway); weekly: 20–30 min.; monthly: < 60 min. |
| Maintenance records kept onboard for user/vendor | no/no |
| Maintenance training demonstration module onboard | no |
| Training included with purchase/Avg. time for basic user training | yes (1 training slot)/3 days (at vendor or customer site) |
| Advanced operator training/Extra charge for follow-up or advanced training | yes (at vendor site)/yes |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (contract dependent)/— |
| Distinguishing features (supplied by company) | microvolume technology for improved cost efficiency; big lab automation in a small footprint; processes 1,200 tests per hour with ion-selective electrodes; 100 programmable applications; optional autoloader |