Webinars and Sponsored Roundtables — Register Now
Tuesday, July 21, 2026, 11:00-11:30 AM CT
- Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
- Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
- Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.
Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.
Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Bio-Rad Laboratories Clinical Diagnostics Group
Geenius System
| Company | Bio-Rad Laboratories Clinical Diagnostics Group |
|---|---|
| Name of instrument | Geenius System |
| Contact | Maria Crisostomo |
| City, State | Hercules, CA |
| Phone | 800-224-6723 |
| Website | |
| Type of instrument | immunoassay |
| List price/First year sold in U.S. | —/2014 |
| Targeted hospital bed size/Targeted test volume | all/— |
| Company manufactures instrument | yes |
| Other models in this family of analyzers | — |
| No. of units in clinical use in U.S./Outside U.S. (countries) | >450/>700 (Europe, Middle East, Africa, Asia-Pacific, Canada, Latin America) |
| Dimensions (H × W × D)/Instrument footprint | 5.9 × 7.6 × 5.9 in./0.31 sq. ft. |
| Weight empty/Weight fully loaded | 2.1 lbs./~2.1 lbs. |
| No. of different measured assays onboard simultaneously | 2 |
| No. of user-definable (open chemistry) channels | — |
| Test throughput per hour/Assay run time | ~3/15–30 min. (avg. 20 min.) |
| No. of direct ion-selective electrode channels | — |
| Detection methods | — |
| Stat time until completion/specimen throughput for Ion-selective electrode | — |
| Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel | — |
| Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel | — |
| Typical time delay from ordering stat test until aspiration of sample | — |
| Fully automated microplate immunoassay system | no |
| Methodologies supported | lateral flow immunochromatography |
| Separation methodologies | none necessary |
| Stat time until completion of a ß-hCG test | — |
| Stat time until completion of a cTn test | — |
| • Typical time delay from test order to aspiration of sample | — |
| Reagents refrigerated onboard/Reagents ready to use | no (2°–30°C)/yes |
| Reagent lot tracking/Reagent inventory | yes/no |
| Reagent form/Reagents barcoded | dry chemistry (closed reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | — |
| Walkaway capability/Walkaway duration | no/— |
| Design of sample-handling system | — |
| Uses washable cuvettes/Uses disposable cuvettes | no/no |
| Min.–max. sample volume that can be aspirated at one time | — |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 15 µL (whole blood), 5 µL (serum, plasma)/15 µL (whole blood), 5 µL (serum, plasma)/— |
| Dedicated pediatric sample cup | no |
| Primary tube sampling | — |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | — |
| Pierces caps on primary tubes | no |
| Protects against probe collision | no |
| Detects clots/liquid level/short sample | no/no/no |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | hemolysis, icterus, lipemia, clots not available |
| Dilutes patient samples onboard/Susceptibility to carryover | no/— |
| Automatic rerun capability | no |
| Sample volume can be diluted to rerun out-of-linear-range high results | no |
| Sample volume can be concentrated to rerun out-of-linear-range low results | no |
| Autocalibration/Multipoint calibration supported | —/no |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | — |
| Automatic programmable start/Automatic programmable shutdown | yes/no |
| Onboard real-time QC/Onboard software capability to review QC | yes/yes |
| Supports multiple QC lot numbers per analyte | yes |
| Waste management | manually by user |
| Sample barcode-reading capability/Autodiscrimination | yes (Interleaved 2 of 5, Codabar, Code 39, Code 128, Data Matrix)/— |
| Lab can control analyzer from remote computer | no |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | no |
| UPS backup power supply | no |
| Data-management capability/LIS or EHR systems interfaced | onboard/Epic |
| LIS interface provided/Bidirectional interface capability | no/no |
| Modem servicing provided/Service engineer on-site response time | no/— |
| Mean time between failures | — (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: < 5 min.; weekly: < 5 min.; monthly: — |
| Maintenance records kept onboard for user/vendor | no/some records (5-year maintenance) |
| Maintenance training demonstration module onboard | no |
| Training included with purchase/Avg. time for basic user training | yes (1 training slot)/~2 hrs. (at customer site) |
| Advanced operator training/Extra charge for follow-up or advanced training | no/— |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year)/— |
| Distinguishing features (supplied by company) | fast: ~ 20 min. to results; traceability: positive identification of controls and patients; results interpretation: system software performs automated interpretation of band identification with HIV 1/2 differentiation |