Webinars and Commercial Conversations — Register Now

Tuesday, November 10, 2026, 1:00 PM-2 PM ET
Join us for a session to help improve diagnostic accuracy in your practice when scoring HER2 IHC 0 with faint, incomplete membrane staining in ≤10% of tumor cells vs IHC 0 with no membrane staining detected in patients with mBC.

Webinar presenter Samuel Caughron, MD, FCAP, Chief Strategy Officer, MAWD Pathology, Medical Director of Laboratory, AdventHealth Kansas City, Medical Director of Laboratory, Labcorp, President, Member & Director, Pathology Ventures, LLC

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Monday, November 16, 2026, 12:30 PM-2 PM ET
Hear experts discuss a multidisciplinary approach to oncopathology for HER2
assessments for solid tumors in the absence of a companion diagnostic.

Webinar presenters Funda Meric-Bernstam, MD, Chair, Department of Investigational Cancer Therapeutics Medical Director, Institute for Personalized Cancer Therapy, The University of Texas MD Anderson Cancer Center, Houston, Texas, and Emina E. Torlakovic, MD, PhD, College of Medicine, University of Saskatchewan, Canadian Biomarker Quality Assurance, Saskatoon, Saskatchewan, Canada, and Carol Cheung, MD, PhD, JD, FRCPC, Deputy Director, Canadian Biomarker Quality, Assurance—Programme canadien d’assurance de la qualité des biomarqueurs

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, November 18, 2026, 12:00 PM-1 PM ET
Join leading pathology experts, Savitri Krishnamurthy, MD, and Marilyn Bui, MD, PhD, for a webinar exploring potential challenges in HER2 IHC testing for breast cancer, emerging evidence supporting digital and computational pathology as assistive tools for pathologists in HER2 IHC assessment, and practical considerations for real-world implementation and adoption.

Webinar presenters Savitri Krishnamurthy, MD, Professor of Pathology, Department of Anatomical Pathology The University of Texas MD Anderson Cancer Center, Houston, Texas, and Marilyn Bui, MD, PhD, Surgical Pathologist and Cytopathologist Member and Professor, Departments of Pathology, Machine Learning, and Translational Pathology, Scientific Director, Analytic Microscopy Core Chair, Women in Oncology Executive Board Moffitt Cancer Center, Tampa, Florida

CAP TODAY does not endorse any of the products or services named within. This program is being sponsored by Daiichi Sankyo, Inc. and AstraZeneca. The speakers are being compensated for their presentations. The program is not CME accredited and may not be used for CME credit.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Wednesday, December 9, 2026, 12 PM-1 PM ET
Hear an expert pathologist discuss the role of HER2 IHC testing and scoring in solid tumors including endometrial, ovarian, cervical, bladder, non-small cell lung, colorectal, and biliary cancers

Webinar presenter Michelle Shiller, DO, MSPT, Baylor Sammons Cancer Center; Fulgent Genetics; Texas Cancer Interception Institute

CAP TODAY does not endorse any of the products or services named within. This program is intended for US healthcare professionals. This program is being sponsored by AstraZeneca. The speaker is being compensated for the presentation. The program is not CME accredited and may not be used for CME accreditation.

Moderated by: Bob McGonnagle, Publisher, CAP TODAY

Subspecialties

Interactive Product Guides

Manage Subscription

To receive CAP TODAY magazine, please subscribe here.
For change of address, mail new information to: CAP TODAY Circulation, 325 Waukegan Road, Northfield, IL 60093-2750 or visit here.

Product Spotlight

Bio-Rad Laboratories Clinical Diagnostics Group

PR4100 Microplate Reader

Company

Bio-Rad Laboratories Clinical Diagnostics Group

Name of instrument

PR4100 Microplate Reader

Contact

Maria Crisostomo   

Email

maria_crisostomo@bio-rad.com

City, State

Hercules, CA

Phone

800-224-6723   

Website

http://www.bio-rad.com

Type of instrument

immunoassay

List price/First year sold in U.S.

—/2012

Targeted hospital bed size/Targeted test volume

—

Company manufactures instrument

yes

Other models in this family of analyzers

—

No. of units in clinical use in U.S./Outside U.S. (countries)

—

Dimensions (H × W × D)/Instrument footprint

5.3 × 13.7 × 7.4 in./—

Weight empty/Weight fully loaded

5.7 lbs./—

No. of different measured assays onboard simultaneously

—

No. of user-definable (open chemistry) channels

—

Test throughput per hour/Assay run time

—

No. of direct ion-selective electrode channels

—

Detection methods

—

Stat time until completion/specimen throughput for Ion-selective electrode

—

Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel

—

Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel

—

Typical time delay from ordering stat test until aspiration of sample

—

Fully automated microplate immunoassay system

no

Methodologies supported

enzyme immunoassay

Separation methodologies

none necessary

Stat time until completion of a ß-hCG test

—

Stat time until completion of a cTn test

—

• Typical time delay from test order to aspiration of sample

—

Reagents refrigerated onboard/Reagents ready to use

no/—

Reagent lot tracking/Reagent inventory

no/no

Reagent form/Reagents barcoded

liquid chemistry (open reagent system)/—

Separate reagent pack for each specimen/for each test run

—

Walkaway capability/Walkaway duration

no/—

Design of sample-handling system

batch, benchtop

Uses washable cuvettes/Uses disposable cuvettes

no/no

Min.–max. sample volume that can be aspirated at one time 

—

Min. reaction volume/Min. specimen volume/Min. dead volume

—

Dedicated pediatric sample cup

no

Primary tube sampling

no

Accommodates most standard tube sizes/Accepts nonstandard tube sizes

no (microplate reader)/no (microplate reader)

Pierces caps on primary tubes

no

Protects against probe collision

no

Detects clots/liquid level/short sample

yes/yes/no

Detection or quantitation for hemolysis, icterus, lipemia, clots

hemolysis, icterus, lipemia, clots not available

Dilutes patient samples onboard/Susceptibility to carryover

no/—

Automatic rerun capability

no

Sample volume can be diluted to rerun out-of-linear-range high results

no

Sample volume can be concentrated to rerun out-of-linear-range low results

no

Autocalibration/Multipoint calibration supported

no (calibrants are not stored onboard)/no

Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays

—

Automatic programmable start/Automatic programmable shutdown

no/no

Onboard real-time QC/Onboard software capability to review QC

no/no

Supports multiple QC lot numbers per analyte

no

Waste management

manually by user

Sample barcode-reading capability/Autodiscrimination

yes (Interleaved 2 of 5, Codabar, Code 39, Code 128)/no

Lab can control analyzer from remote computer

no

Instrument can diagnose its own malfunctions

no (operator intervention required to order parts)

System malfunctions can be diagnosed via remote monitoring

no

UPS backup power supply

no

Data-management capability/LIS or EHR systems interfaced

no/—

LIS interface provided/Bidirectional interface capability

no/no

Modem servicing provided/Service engineer on-site response time

no/—

Mean time between failures

—

Average scheduled maintenance time by lab personnel

—

Maintenance records kept onboard for user/vendor

no/no

Maintenance training demonstration module onboard

no

Training included with purchase/Avg. time for basic user training

yes (2 training slots)/1 day (at customer site)

Advanced operator training/Extra charge for follow-up or advanced training

no/yes

Warranty provided/Cost of annual service contract (24 h/7 d)

yes/—

Distinguishing features (supplied by company)

comprehensive data-analysis software for full traceability; LIS connectivity; compact size–space saver

More products
in this guide

Alinity ci-series
ASI Evolution RPR Syphilis Analyzer
DxI 9000 Access Immunoassay Analyzer
Pictus 700 (P700)
Agility Automated ELISA System
AIX1000 Agglutination Instrument