Webinars and Sponsored Roundtables — Register Now
Tuesday, July 21, 2026, 11:00-11:30 AM CT
- Explain how transparency and manufacturer partnerships improve quality, consistency, and decision-making confidence in specimen management.
- Evaluate blood collection tubes beyond cost and commodity assumptions, incorporating clinical impact and risk into decision-making.
- Assess the potential risk points when using a blood collection device that has not been cleared for a specific purpose.
Roundtable presenters Nick Fingland, PhD, PMP, Senior Director, R&D Operations and Science, BD, and Chris Farnsworth, PhD, D(ABCC), Section Head of Clinical Chemistry, Professor of Pathology and Immunology, Washington University School of Medicine.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Wednesday, July 29, 2026, 1:00-2:00 PM ET
Learn about digital pathology technology that is future-ready, yet practical for today’s
laboratory needs.
Webinar presenters Scott Hammond, Senior Systems Consultant, Digital Pathology Division, Wexner Medical Center, Department of Pathology, and Ursula Hofer, Imaging Technologist, Pathology Digital Imaging Lab, Wexner Medical Center, Department of Pathology, and Sandra Banky, PA(ASCP), Director of Operations, Wexner Medical Center, Department of Pathology.
Moderated by: Bob McGonnagle, Publisher, CAP TODAY
Interactive Product Guides
Product Spotlight
Tosoh Bioscience
AIA-2000
| Company | Tosoh Bioscience |
|---|---|
| Name of instrument | AIA-2000 |
| City, State | Grove City, OH |
| Phone | 800-248-6764 |
| Website | |
| Type of instrument | immunoassay |
| List price/First year sold in U.S. | —/2008 |
| Targeted hospital bed size/Targeted test volume | > 65/monthly: > 1,500 |
| Company manufactures instrument | yes (also sold by McKesson, Henry Schein, Thermo Fisher, Medline) |
| Other models in this family of analyzers | AIA-360, AIA-900 |
| No. of units in clinical use in U.S./Outside U.S. (countries) | ~80/> 1,000 (worldwide) |
| Dimensions (H × W × D)/Instrument footprint | AIA-2000 ST: 50 × 59 × 35 in./AIA-2000 LA: 50 × 59 × 47 in./14.6 sq. ft. |
| Weight empty/Weight fully loaded | 882 lbs./— |
| No. of different measured assays onboard simultaneously | 48 (48 can be run and calibrated at one time) |
| No. of user-definable (open chemistry) channels | 0 |
| Test throughput per hour/Assay run time | 200 (18 min. to first result, 18 sec. for subsequent results)/18–58 min. (avg. 38 min.) |
| No. of direct ion-selective electrode channels | — |
| Detection methods | — |
| Stat time until completion/specimen throughput for Ion-selective electrode | — |
| Stat time until completion/specimen throughput for Ion-selective electrode basic metabolic panel | — |
| Stat time until completion/specimen throughput for Ion-selective electrode complete metabolic panel | — |
| Typical time delay from ordering stat test until aspiration of sample | — |
| Fully automated microplate immunoassay system | no |
| Methodologies supported | fluorescence enzyme immunoassay (FEIA) |
| Separation methodologies | — |
| Stat time until completion of a ß-hCG test | 18 min. |
| Stat time until completion of a cTn test | 18 min. |
| • Typical time delay from test order to aspiration of sample | 18 sec. |
| Reagents refrigerated onboard/Reagents ready to use | no/yes |
| Reagent lot tracking/Reagent inventory | yes/yes |
| Reagent form/Reagents barcoded | dry chemistry (closed reagent system)/yes |
| Separate reagent pack for each specimen/for each test run | no/no |
| Walkaway capability/Walkaway duration | yes/~3 hours or 200 specimens or 960 tests |
| Design of sample-handling system | rack |
| Uses washable cuvettes/Uses disposable cuvettes | no/no |
| Min.–max. sample volume that can be aspirated at one time | 2–100 µL |
| Min. reaction volume/Min. specimen volume/Min. dead volume | 10 µL/10 µL/100 µL |
| Dedicated pediatric sample cup | no |
| Primary tube sampling | yes |
| Accommodates most standard tube sizes/Accepts nonstandard tube sizes | yes/no |
| Pierces caps on primary tubes | no |
| Protects against probe collision | yes |
| Detects clots/liquid level/short sample | yes/yes/yes |
| Detection or quantitation for hemolysis, icterus, lipemia, clots | detection for clots; hemolysis, icterus, lipemia not available |
| Dilutes patient samples onboard/Susceptibility to carryover | yes (can be programmed to perform dilutions prior to analysis)/— |
| Automatic rerun capability | yes |
| Sample volume can be diluted to rerun out-of-linear-range high results | yes |
| Sample volume can be concentrated to rerun out-of-linear-range low results | no |
| Autocalibration/Multipoint calibration supported | no (calibrants are not stored onboard)/yes (recommended avg. frequency: 90 days) |
| Typical calibration frequency for ISE/therapeutic drugs/drugs of abuse/general chemistries/immunoassays | —/—/—/—/90 days |
| Automatic programmable start/Automatic programmable shutdown | no/no |
| Onboard real-time QC/Onboard software capability to review QC | no/yes |
| Supports multiple QC lot numbers per analyte | yes |
| Waste management | automated collection onboard instrument or direct to drain |
| Sample barcode-reading capability/Autodiscrimination | yes (Interleaved 2 of 5, Codabar, Code 39, Code 128, JAN)/yes |
| Lab can control analyzer from remote computer | no |
| Instrument can diagnose its own malfunctions | yes (operator intervention required to order parts) |
| System malfunctions can be diagnosed via remote monitoring | no |
| UPS backup power supply | yes |
| Data-management capability/LIS or EHR systems interfaced | onboard/Clinisys, Oracle Health, MedLab, SCC Soft Computer, SchuyLab, IDEAS, more |
| LIS interface provided/Bidirectional interface capability | no/yes (host query) |
| Modem servicing provided/Service engineer on-site response time | no/within 24 hrs. |
| Mean time between failures | 106 days (displays error codes for troubleshooting) |
| Average scheduled maintenance time by lab personnel | daily: 5 min.; weekly: 5 min.; monthly: 10 min. |
| Maintenance records kept onboard for user/vendor | yes/yes (both include audit trail of who replaced parts) |
| Maintenance training demonstration module onboard | no |
| Training included with purchase/Avg. time for basic user training | yes (2 training slots)/4 days (at vendor site) |
| Advanced operator training/Extra charge for follow-up or advanced training | no/— |
| Warranty provided/Cost of annual service contract (24 h/7 d) | yes (1 year from installation date)/— |
| Distinguishing features (supplied by company) | dry reagent with no biotin interference, unit dose test cup, 90-day calibration stability for most assays; 3 separate incubators to minimize processing time; dual clot detection, automated dilutions, and pretreament; available in 2 models–standard (ST) and line automation (LA)–appropriate for stat and routine use |